MICROHARDNESS OF THE APPROXIMAL AND PULPAL SURFACES IN CLASS II COMPOSITE RESTORATIONS: AN IN VITRO STUDY

Date
2008
Author
Efes, Begum Gusray
GÖMEÇ, Ömer Yavuz
DÖRTER, Can
Erdilek, Dina
YAMAN, BATU CAN
Metadata
Show full item record
Abstract
The aim of this in vitro study was to examine the surface microhardness of composite resin materials when placed in class II cavities using two different matrix systems (Quickmat, Polydentia and Lucifix, HaweNeos). A hybrid composite (Tetric EvoCeram-Ivoclar Vivadent), two nanohybrid composites (Grandio-Voco, Synergy D6-Coltene/Whaledent) and a nanofil composite (Filtek Supreme XT-3M Espe) were placed in the silicon dublicates of class II cavities which were primarly prepared in plastic teeth without levels (4x4x4) mm (n=160). The cavity was prepared in plastic teeth (4mm bucco-lingual x 4 mm depth x 3mm mesio-distal) (KaVo, EWL model). Cavosurface margins were not beveled. The impressions of the tooth with the cavity preparation were taken using polyvinyl siloxan(Speedy/PuttyLigth-Coltene). A silicon material (AffinisPrecious-Coltene) was injected in the impressions and a silicon mold of the teeth and the cavity were obtained. The prepared silicon teeth were mounted in plastic jaw (KaVo, EWL model) to simulate proximal contact. Metal sectional matrix (Quickmat-Polydentia) (n=20) and clear matrix system (Lucifix-HaweNeos) (n=20) were prepared for each tooth. Wedges were used to stabilize the matrix. The cavities were restored incrementally in oblique layers with all four restorative materials. And each increment was light cured for 40 s (Celalux-Voco). The restorations were then removed from the cavities and surface hardness of the proximal and axio-pulpal surfaces were immediatly measured with Microhardness Vickers Test device (Clemex CMT 7, Clemex Labs.). Data were statistically analyzed with one way ANOVA and Tukey's Multiple Comprassion test. No significant differences were found between metal matrix and clear matrix (p>0.05). Microhardness of axio-pulpal surfaces were found significantly lower than the proximal surfaces for each restorative materials (p<0.05). Metal or clear matrix systems both could be used in the class II cavities in regard the surface microhardness of composite resins materials.
URI
http://hdl.handle.net/20.500.12627/178792
Collections
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypes

My Account

LoginRegister

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV