• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   Home
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • View Item
  •   Home
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

In Vitro Comparison of the Retentive Properties of Ball and Locator Attachments for Implant Overdentures

Date
2014
Author
Bilgin, Tayfun
Geckili, Onur
TURK, Pinar Eren
TURK, Yasin
GUNAY, Volkan
Metadata
Show full item record
Abstract
Purpose: To compare the retentive properties of ball and locator attachments during 5,000 insertion-separation cycles, corresponding to approximately 4.5 years of clinical use. Materials and Methods: Four dental implants (diameter, 3.8 mm; length, 12 mm) were inserted into the prepared beds of two polyethylene blocks. Twenty acrylic prosthetic components were fabricated and connected to the ball and locator abutments. Tensile force was applied to the prosthetic components until the attachments were separated from the abutments. All samples were subjected to 5,000 insertion-separation cycles. Retention forces were measured after 10, 100, 200, 300, 400, 500, 1,000, 1,500, 2,000, 3,000, 4,000, and 5,000 insertion-separation cycles. Additionally, the wear of the attachments was measured using scanning electron microscopy. Data were analyzed to determine statistical equivalence among the two different attachments using the Student t test procedure and the Mann-Whitney U test procedure (alpha = .05). Results: Ball attachments showed significant retention loss after 100, 200, 400, 500, 1,500, and 4,000 cycles, and the locator attachments showed significant retention loss after 100, 200, 300, 500, and 3,000 cycles as compared with the previous cycle (P .05). No significant difference was detected between the wear on the two attachment systems after 5,000 cycles (P > .05). Conclusion: Both attachment systems showed decreased retentive forces after 5,000 insertion-separation cycles. However, after 5,000 insertion-separation cycles, locator attachments showed better retentive properties than ball attachments.
URI
http://hdl.handle.net/20.500.12627/95182
https://doi.org/10.11607/jomi.3621
Collections
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypes

My Account

LoginRegister

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV