• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   Home
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • View Item
  •   Home
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Technetium-99m-MIBI scintigraphy in pulmonary tuberculosis

Date
1996
Author
Kanmaz, B
Uslu, I
Uzun, A
Sayman, HB
Sonmezoglu, K
Onsel, C
Camsari, G
Atay, S
Cetin, S
Erdil, YT
Metadata
Show full item record
Abstract
We investigated the usefulness of Tc-99m-methoxyisobutylisonitrile scintigraphy in patients with known or suspected pulmonary tuberculosis (PTB) in comparison with radiological and bacteriological findings. Methods: Thirty-six patients aged 13-59 yr were scanned 15 and 60 min after intravenous injection of 370 MBq (10 mCi) Tc-99m-methoxyisobutylisonitrile. Twenty-four patients had active PTB proven by chest radiograph and sputum examinations, two had miliary tuberculosis and ten were suspected of having relapsed PTB with negative sputum examinations and indeterminate chest radiographs, In 12 patients Tc-99m-MIBI imaging was repeated 1-3 mo after chemotherapy. Results: Of 24 patients with active localized PTB, 22 (92%) showed increased focal uptake of Tc-99m-MIBI, but two patients with minimal infiltration on chest radiographs had no accumulation of Tc-99m-MIBI. Both patients with miliary PTB showed diffuse Tc-99m-MIBI uptake in the lungs. Among 10 patients with suspicion of relapse, Tc-99m-MIBI scans were true-positive in 4 of 5 patients (80%) with culture-proven tuberculosis and false-positive in 2 of 5 (40%) patients with negative sputum cultures, For repeat imaging, 6 of 10 patients with active localized PTB showed reduced MIBI uptake, which correlated with chest radiograph findings, and one patient had increased MIBI uptake again concordant with clinical and radiological findings which were suggestive of resistance to first line chemotherapy of tuberculosis. The other three patients showed no significant scintigraphic changes despite clinical and partial radiological regression. Conclusion: Active PTB granulomas generally present considerable Tc-99m-MIBI uptake that is most probably related to disease activity. Therefore, Tc-99m-MIBI scanning could be used in the detection and follow-up of active PTB as a complement to routine techniques.
URI
http://hdl.handle.net/20.500.12627/91893
Collections
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypes

My Account

LoginRegister

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV