Direct Current Electric Stimulation in Implant Osseointegration: An Experimental Animal Study With Sheep

Tarih
2013
Yazar
Gursoy, Bahar
Devecioglu, Yalçın
Akta, Mustafa
KÜRKÇÜ, MEHMET
Benlidayi, Emre
DERGİN, GÜHAN
Üst veri
Tüm öğe kaydını göster
Özet
In an effort to obtain a high-quality bone-implant interface, several methods involving alteration of surface morphological, physicochemical, and biochemical properties are being investigated. The aim of our study was to increase the osseointegration rate and quality and decrease the waiting period of dental implants before loading by using a microelectric implant stimulator device. It imitates rnicroelectrical signals, which occur in bone fractures described in terms of piezoelectric theory. A single dental implant (Zimmer Dental), 3.7 mm in diameter, was inserted into the tibia of sheep bilaterally. Twenty-four dental implants were inserted into 12 sheep. Implant on the tibia of each sheep was stimulated with 7.5 mu A direct current (DC), while the other side did not receive any stimulation and served as a control. Animals were sacrificed 1, 2, and 3 months after implantation. Bone segments with implants were processed with unclassified method. The determination of new bone formation and osseointegration around the dental implants was investigated by means of undecalcified method, histomorphologically. No statistically significant difference in bone-to-implant contact (BIC) ratio, osteoblastic activity, and new bone formation was found between the stimulation group and the control group at the late phase of healing (4, 8, and 12 weeks). No evidence was found that electric stimulation with implanted 7.5 mu A DC is effective at late phase implant osseointegration on a sheep experimental model.
Bağlantı
http://hdl.handle.net/20.500.12627/75236
https://doi.org/10.1563/aaid-joi-d-10-00172
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV