Determination of some discharge parameters of horizontally discharged cold-dense wastewaters

Tarih
2018
Yazar
Sezgin, Naim
Üst veri
Tüm öğe kaydını göster
Özet
Thermal pollution is defined as increase or decrease in temperature of an aquatic environment which may be ocean, lake or river by human influence. A common cause of thermal pollution is the use of water as a cooling and heating system by power plants, liquefied natural gas (LNG) re-gasification terminals and industrial manufacturers. One of the important sources of thermal effluents is cold water discharges, which are mainly originated from LNG re-gasification terminals from open cycle heating units. Cold water can be frequently discharged into coastal waters. Due to its high density, cold water discharge is a kind of negatively buoyant jet. Because of some undesired effects of cold water on receiving water species, should be discharged properly into the marine environment with a high level of initial dilution. Some discharge parameters of horizontally discharged cold-dense wastewater such as initial dilutions, impingement points were determined in a laboratory system using circular port in this study. To determine the behavior of the cold-dense wastewater (wastewater jet geometry) Rhodamine B as a colorant was added to the wastewater. A high-resolution camera was used to take snapshots of the colored cold-dense wastewater. Temperature changes (dilutions) in the cold-dense wastewater jet centerline were detected with sensitive thermal probes. To gain different densities, three discharge temperature differences were used as -3 degrees C, -5 degrees C and -7 degrees C. According to the results of this study, it was determined that the cold water discharges behaved like a negative buoyant jet. In addition, it was calculated that the averages of the normalized impingement point and initial dilution of the cold water were found 2.333 and 0.491, respectively.
Bağlantı
http://hdl.handle.net/20.500.12627/6524
https://doi.org/10.5505/pajes.2017.17136
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV