• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Influence of dry and wet curing conditions on compressive strength of silica fume concrete

Tarih
2005
Yazar
ATİŞ, Cengiz Duran
BİLİM, Cengiz Duran
SEVERCAN, M.H.
KILIÇ, ALAETTİN
KARAHAN, Okan
ÖZCAN, Fatih
Üst veri
Tüm öğe kaydını göster
Özet
This paper reports a part of an ongoing laboratory investigation in which the compressive strength of silica fume concrete is studied under dry and wet curing conditions. In the study, a total of 48 concretes, including control Portland cement concrete and silica fume concrete, were produced with four different water-cement ratios (0.3, 0.4, 0.5, 0.6), three different cement dosages (350, 400, 450kg/m(3)) and three partial silica fume replacement ratios (10%, 15%, 20%). A hyperplastisizer was used in concrete at various quantities to provide and keep a constant workability. Three cubic samples produced from fresh concrete were demoulded after a day; then, they were cured at 20 +/- 2 degrees C with 65% relative humidity (RH), and three other cubic samples were cured at 20 +/- 2 degrees C with 100% RH until the samples were used for compressive strength measurement at 28 days. The comparison was made on the basis of compressive strength between silica fume concrete and control Portland cement concrete. Silica fume concretes were also compared among themselves. The comparisons showed that compressive strength of silica fume concrete cured at 65% RH was influenced more than that of Portland cement concrete. It was found that the compressive strength of silica fume concrete cured at 65% RH was, at average, 13% lower than that of silica fume concrete cured at 100% RH. The increase in the water-cementitious material ratios makes the concrete more sensitive to dry curing conditions. The influence of dry curing conditions on silica fume concrete was marked as the replacement ratio of silica fume increased. (c) 2005 Elsevier Ltd. All rights reserved.
Bağlantı
http://hdl.handle.net/20.500.12627/64135
https://doi.org/10.1016/j.buildenv.2004.12.005
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV