• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   Home
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • View Item
  •   Home
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Corneal Viscoelastic Differences Between Pseudoexfoliative Glaucoma and Primary Open-angle Glaucoma

Date
2013
Author
Ozkok, Ahmet
Tamcelik, Nevbahar
Sarici, Ahmet M.
Cicik, Erdogan
Ozdamar, Akif
Metadata
Show full item record
Abstract
Purpose:The aims of this study were to assess the biomechanical properties of corneas with pseudoexfoliative glaucoma (PEXG) and to compare them with those of patients with primary open-angle glaucoma (POAG).Methods:This prospective, comparative case series consisted of 73 eyes of 73 patients, 35 eyes with PEXG (PEXG group) and 38 eyes with POAG (POAG group). Corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPCC), and Goldmann-correlated intraocular pressure (IOPG) were determined by using ocular response analyzer (ORA). IOP using Goldmann applanation tonometer (GAT) and ultrasonic central corneal thickness (CCT) were also measured for each eye. Exclusion criteria included refractive error/astigmatism of >3.00 D, history of intraocular surgery, corneal disease, angle-closure glaucoma, and secondary glaucoma other than PEXG. In cases where both eyes were eligible, the right eye was preferred for analysis. The main outcome measures were CH, CRF, IOPCC, IOPG, and GAT. The results were statistically analyzed by using t test, general linear model, and the Pearson correlation test.Results:The mean CH was found to be significantly lower in patients with PEXG (8.81.4 mm Hg) than those with primary open-angle glaucoma (9.9 +/- 1.2 mm Hg; P=0.0007). The mean CRF was found to be significantly lower in patients with PEXG (9.5 +/- 1.8 mm Hg) than those with POAG (11.1 +/- 1.3 mm Hg; P<0.0001). IOPCC was not significantly different between the groups (PEXG, 16.7 +/- 2.5 mm Hg; POAG, 16.9 +/- 2.4 mm Hg; P=0.72). IOPG was significantly lower in PEXG group (14.7 +/- 2.7 mm Hg) compared with the POAG group (16.5 +/- 2.5 mm Hg; P=0.004). GAT was significantly lower in the PEXG group (14.6 +/- 2.7 mm Hg) compared with the POAG group (16.4 +/- 2.8 mm Hg; P=0.007). There was no significant difference between the groups regarding mean CCT (PEXG, 546.1 +/- 34.9 ; POAG, 549.1 +/- 25 ; P=0.66) and mean age (PEXG, 70.3 +/- 8.2; POAG, 67.6 +/- 8.8; P=0.17). The difference between the IOPCC and the GAT was 2.1 and 0.5 mm Hg in both PEXG and POAG groups, respectively.Conclusions:Patients with PEXG had lower CH and CRF values than those with POAG. These findings require further investigation to assess the role of differing corneal biomechanical properties between the 2 groups and its association with poor prognosis among patients with PEXG.
URI
http://hdl.handle.net/20.500.12627/52009
https://doi.org/10.1097/ijg.0000000000000036
Collections
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypes

My Account

LoginRegister

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV