• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Influence of isolation system characteristic strength on the earthquake behavior of base-isolated liquid storage tanks

Tarih
2018
Yazar
GÜLER, Elif
GAZİ, HATİCE
ALHAN, Cenk
Üst veri
Tüm öğe kaydını göster
Özet
Earthquake performance of liquid storage tanks may be substantially improved by base-isolation. However, the possibility of facing large isolator displacements in case of large magnitude near-fault earthquakes threatens the safety of these structures, which may be realized if the period of the velocity pulses that typically exist in the near-fault earthquake records are close to their isolation periods. Increasing isolation system characteristic strength may help reducing the aforementioned large isolator displacements but this in turn may have a negative impact on the superstructure response. Therefore, this study aims to investigate the influence of the characteristic strength of the isolation system on the behavior of base-isolated liquid storage tanks under representative historical near-fault and far-fault earthquakes by making use of a set of benchmark tank models with different levels of isolation system characteristic strength ratios. Numerical modeling and non-linear time history analyses are carried out via the academic software 3DBASIS-ME,which offers the possibility of conducting such modeling and analysis following a highly preferred mechanical analog that is able to take the deformability of the tank wall and sloshing of the fluid into account by considering the fundamental sloshing and fundamental fluid-tank modes of vibration as single degree of freedom systems sharing a common isolation base-mat. The seismic responses including isolation system displacement, sloshing fluid displacement, isolation system shear force, fluid-tank shear force, and sloshing fluid shear force are reported in a comparative manner. Results show that while higher characteristic strength effectively reduces large base displacements observed under near-fault earthquakes, it may cause significant amplifications in the superstructure responses particularly under far-fault earthquakes.
Bağlantı
http://hdl.handle.net/20.500.12627/28604
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV