• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Evaluation of Teicoplanin Resistance Detected by Automated System in Coagulase Negative Staphylococci: A Comparison with Gradient Test and Broth Microdilution Methods

Tarih
2020
Yazar
Buyukyanbolu, Ecem
Aktas, Elif
Baris, Ayse
Malkocoglu, Gulsah
Aslan, Feride Merve
Bayraktar, Banu
Üst veri
Tüm öğe kaydını göster
Özet
Upon the observation of an increase in teicoplanin resistance rates in coagulase negative staphylococci (CoNS) isolates determined by the automated system, we aimed to compare the automated system and gradient test methods with the gold standard broth microdilution method. In addition, the effect of standard antimicrobial susceptibility guidelines on teicoplanin susceptibility test results in CoNS was investigated. A total of 81 CoNS isolates, 52 resistant and 29 susceptible to teicoplanin determined by automated system (Phoenix, Becton Dickinson, USA), were tested. The minimum inhibitory concentration (MIC) values were determined by gradient test (M.I.C. Evaluators, OXOID, UK) and broth microdilution methods. Susceptibility categories were determined according to EUCAST and CLSI criteria and the results were compared. Among 29 isolates found to be susceptible by automated system, one isolate was found resistant by gradient and broth microdilution tests. Of the 52 resistant isolates determined by automated system, 12 (23%) were found to be resistant by gradient test and 22 (42.3%) were resistant by broth microdilution. According to CLSI criteria, no resistant isolates were detected by broth microdilution and six isolates were intermediately susceptible while, two isolates were detected to be resistant and five isolates were found to be intermediately susceptible by the gradient test. In conclusion, compared to microdilution, teicoplanin resistance was detected at a higher rate in CoNS isolates by the automated system used. On the other hand, the gradient test method which is frequently used for confirmation was not reliable in MIC values close to the EUCAST breakpoint values (4 mu g/mL). In addition, lower resistance rates were observed when the CLSI breakpoints were used in gradient test and broth microdilution methods.
Bağlantı
http://hdl.handle.net/20.500.12627/2655
https://doi.org/10.1007/s00284-020-02144-7
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV