• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Intrathecal use of gadobutrol for gadolinium-enhanced MR cisternography in the evaluation of patients with otorhinorrhea

Tarih
2020
Yazar
Arslan, Serdar
KIZILKILIÇ, Osman
Korkmazer, Bora
Islak, Civan
Kocer, Naci
Dogan, Sebahat Nacar
Salt, Vefa
Üst veri
Tüm öğe kaydını göster
Özet
Purpose Intrathecal gadolinium-enhanced MR cisternography (IGE-MRC) has a high sensitivity to detect accurate localization of cerebrospinal fluid (CSF) leakage in otorhinorrhea patients. Our purpose in this study was to describe our experience in analyzing clinically suspected CSF leakage by IGE-MRC by using gadobutrol with emphasis on its safety and diagnostic performance. Methods We retrospectively reviewed our imaging and clinical database for the evaluation of patients admitted to our clinic with complaints of otorhinorrhea between 2017 and 2019. Two radiologists evaluated the imaging studies independently. Consensus data was used in the analysis. Medical record review and phone call were used for the follow-up. Results Of the 85 patients included in the retrospective analysis, 82 (96.5%) had rhinorrhea and 3 (3.5%) had otorrhea. Overall, 29 patients (34.1% of all patients) underwent operation for repair of the CSF leakage site. Beta-transferrin test was available and positive in 33 patients (38.8%). Five (5.9%) patients complained headaches after the procedure and complaints were resolved with increased water intake. Postprocedurally, 3 patients (3.5%) had vertigo and 1 patient (1.2%) complained nausea but spontaneous regression were observed in a few hours. None of the patients experienced a significant complication or adverse reaction during follow-up period. Sixty-seven patients (78.8%) had medical record and telephone follow-up. Mean follow-up duration with call was 14.2 months. Conclusion IGE-MRC is a minimally invasive and highly sensitive imaging technique. The current results during our follow-up demonstrate the relative safety and feasibility of IGE-MRC by using gadobutrol to evaluate CSF leakage.
Bağlantı
http://hdl.handle.net/20.500.12627/2594
https://doi.org/10.1007/s00234-020-02463-3
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV