A novel flow injection amperometric method for sensitive determination of total antioxidant capacity at cupric-neocuproine complex modified MWCNT glassy carbon electrode

Date
2022
Author
ARDA, AYŞEM
APAK, MUSTAFA REŞAT
DİLGİN, YUSUF
AYAZ, SELEN
Metadata
Show full item record
Abstract
A novel amperometric method is presented for the determination of total antioxidant capacity in flow injection analysis (FIA) system using copper(II)-neocuproine complex modified on Nafion-functionalized multi-walled carbon nanotube-glassy carbon electrode ([Cu(Ncp)(2)(2+)]/Nf@f-MWCNT/GCE). Cyclic voltammetric studies showed that the modified electrode exhibits a very well-formed reversible redox couple for Cu(II)-/Cu(I)-complex. In addition, the [Cu(Ncp)(2)(2+)]/[Cu(Ncp)(2)(+)] redox pair shows very good electrocatalytic activity towards the oxidation of polyphenolic compounds (PPhCs) such as trolox, catechin, and quercetin due to the enhancement of the anodic peak current of the redox couple in the presence of these analytes. This electrocatalytic oxidation current at the [Cu(Ncp)(2)(2+)]/Nf@f-MWCNT/GCE was used for flow injection (FI) amperometric determination of PPhCs. FI amperometric-time curves recorded under optimized conditions (applied potential: + 0.6 V vs. Ag/AgCl/KCl(0.10 M), flow rate: 2 mL/min) showed that the proposed electrode had a wide linear range (LR) with a very low detection limit (LOD) for PPhCs. LR and LOD were 0.5-800 and 0.2 mu M for trolox, respectively and 0.50-250 and 0.14 mu M, respectively, for both quercetin and catechin. This sensitive method was successfully applied to the amperometric measurement of total antioxidant capacity (TAC) of some herbal teas, giving compatible results with the spectrophotometric CUPRAC method. The proposed method gave higher rank to fast-reacting antioxidants; it was equally precise but had a wider linear range and lower LOD than the spectrophotometric CUPRAC assay (e.g., LOD for ascorbic acid and gallic acid were 0.07 and 0.08 mu M, respectively), and similar electroanalytical methods using the CUPRAC reagent.
URI
http://hdl.handle.net/20.500.12627/183727
https://doi.org/10.1007/s00604-022-05271-z
Collections
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypes

My Account

LoginRegister

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV