• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   Home
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • View Item
  •   Home
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Endogenous Leptin Concentrations Poorly Predict Metreleptin Response in Patients With Partial Lipodystrophy

Date
2022
Author
Neidert, Adam H.
Brown, Rebecca J.
Walter, Mary
Muniyappa, Ranganath
Oral, Elif Arioglu
MERAL, Rasimcan
Malandrino, Noemi
Metadata
Show full item record
Abstract
Context Leptin replacement with metreleptin improves glycemia and hypertriglyceridemia in severely hypoleptinemic patients with generalized lipodystrophy (GLD), but its effects are variable in partially leptin-deficient patients with partial lipodystrophy (PLD). Objective Compare 3 leptin assays (Study I); identify diagnostic performance of leptin assays to detect responders to metreleptin for each assay (Study II). Design Study I: cross-sectional analysis of average bias between leptin assays. Study II: retrospective analysis of diagnostic accuracy of potential leptin cut points to detect clinical responders to metreleptin. Setting National Institutes of Health; University of Michigan. Participants and Interventions Study I: Metreleptin-naive patients with lipodystrophy (GLD, n = 33, PLD, n = 67) and healthy volunteers (n = 239). Study II: GLD (n = 66) and PLD (n = 84) patients treated with metreleptin for 12 months. Outcome Measures Leptin concentrations by Millipore radioimmunoassay (RIA), Millipore enzyme-linked immunosorbent assay (MELISA), and R&D Systems enzyme-linked immunosorbent assay (RDELISA). Response to metreleptin therapy was defined as either reduction >= 1.0% in A1c or >= 30% in serum triglycerides. Results RDELISA measured 3.0 +/- 9.5 ng/mL higher than RIA; MELISA measured 11.0 +/- 17.8 and 14.0 +/- 19.2 less than RIA and RDELISA, respectively. Leptin by RIA, MELISA, and RDELISA modestly predicted metreleptin response in GLD + PLD [receiver operating characteristic (ROC) area under the curve (AUC) 0.74, 0.69, and 0.71, respectively; P 0.05 for all). The only reproducible cut point identified on sensitivity analyses was RIA leptin 7.2 ng/mL (sensitivity 56%; specificity 78%). Conclusions Three common leptin assays are not interchangeable, and a reliable cut point to select responders to metreleptin was not identified.
URI
http://hdl.handle.net/20.500.12627/183654
https://doi.org/10.1210/clinem/dgab760
Collections
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypes

My Account

LoginRegister

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV