Electrochemical determination of nitroaromatic explosives using glassy carbon/multi walled carbon nanotube/polyethyleneimine electrode coated with gold nanoparticles

Yazar
SAĞLAM, ŞENER
APAK, MUSTAFA REŞAT
ARDA, AYŞEM
Arman, Aysu
Üst veri
Tüm öğe kaydını göster
Özet
The on site/in field detection of explosives has become a rising priority for homeland security and counter-terrorism measures. This work presents the sensitive detection of nitroaromatic explosives using glassy carbon/ multi-walled carbon nanotubes/polyethyleneimine (GC/MWCNTs/PEI) electrode coated with gold nanoparticles (AuNPs). MWCNTs and PEI could be well dispersed in ethanol/water solution, giving rise to a thin and homogeneous film on GCE. The GC/MWCNTs/PEI electrode was electrochemically modified with AuNPs and used for the differential pulse voltammetric (DPV) detection of nitroaromatics. The enhanced detection sensitivities were achieved through 7C-7C and charge-transfer (CT) interactions between the electron-deficient nitroaromatic explosives and donor amine groups in PEI to which gold nanoparticles were linked, providing increased analyte affinity toward the modified GCE. Calibration curves of current intensity versus concentration were linear in the range of 0.05-8 mg L-1 for TNT, 0.2-4 mg L-1 for 2,4-dinitrotoluene (DNT), 1-20 mg L-1 for 2,4-dinitrophenol (2,4-DNP), 0.25-10 mg L-1 for picric acid (PA), and 0.05-4 mg L-1 for 2,4,6-trinitrophenyl-N-methylnitramine (tetryl) with detection limits (LOD) of 15 mu g L-1, 45 mu g L-1, 135 mu g L-1, 30 mu g L-1, and 12 mu g L-1, respectively. The proposed method was successfully applied to the analysis of nitroaromatics in synthetic explosive mixtures and military composite explosives (comp B and octol). The electrochemical method was not affected by possible interferents of electroactive camouflage materials and common soil ions. Method validation was performed against the reference LC-MS method on TNT and PA-contaminated clay soil samples separately.
Bağlantı
http://hdl.handle.net/20.500.12627/179573
https://doi.org/10.1016/j.talanta.2021.122990
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV