• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Does posterior cruciate ligament sacrifice influence dynamic balance after total knee arthroplasty? Comparison of cruciate-retaining and cruciate-substituting designs in bilaterally operated patients

Tarih
2021
Yazar
Guler, Cevaydin
AYDINGÖZ, Önder
Ahmet, Serpil Hulya
Tok, Okan
ÖZŞAHİN, MAHMUT KÜRŞAT
GÜVEN, MEHMET FATİH
KARAİSMAİLOĞLU, BEDRİ
KARA, EYYUP
Üst veri
Tüm öğe kaydını göster
Özet
Purpose This study aimed to evaluate whether the posterior cruciate ligament sacrifice during total knee arthroplasty (TKA) has any effect on postoperative standing balance or not. Methods The patients who underwent bilateral TKA with either CR or PS design were analyzed. 30 patients (10 PS, 20 CR) were included for the final analysis. TKA designs were compared in terms of Lysholm score, range of motion, and balance characteristics including somatosensorial, vestibular, and visual balance scales, adaptation, limits of stability, and weight-bearing/squat tests by computerized dynamic posturography. Results The mean follow-up time was 59 months for CR, 49 months for PS group. The average Lysholm score values were 94 for CR and 95 for PS group, indicating functionally similar patient groups. The average knee flexion was found significantly higher in PS group (114 degrees) compared to CR group (102 degrees) (p = 0.009). In the CR group, motor adaptation tests (toes up/toes down) were found to be better (p = 0.034). In the on-axis velocity parameter (linear goal orientation) of limits of stability test, PS group patients were found to be more successful (p = 0.035). Conclusions The use of CR implants can be recommended in patients with a high risk of falling since they provide better motor adaptation providing rapid reactions to rapid surface changes. Better linear goal orientation in PS group, providing a faster movement in an intended direction, should be considered when planning the ideal implant for the patients with relevant activities.
Bağlantı
http://hdl.handle.net/20.500.12627/176840
https://doi.org/10.1177/23094990211061610
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV