• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   Home
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • View Item
  •   Home
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

High performance liquid chromatographic method with post-column detection for quantification of reducing sugars in foods

Author
Apak, Resat
Akyuz, Esin
Baskan, Kevser Sozgen
Tutem, Esma
Metadata
Show full item record
Abstract
A novel liquid chromatographic analysis method with post-column detection for sugars was developed to improve existing methods in regard to operation time, selectivity, and sensitivity. This method involves separation of reducing sugars on HPLC column at 30 degrees C and 0.8 mL min(-1) flow rate, post-column reaction of sugars with Cu(II)-neocuproine (Nc) reagent at 80 degrees C and 0.3 mL min(-1) flow rate, and measurement of Cu(I)-Nc product at 450 nm. The proposed assay was applied to glucose, fructose, maltose, and lactose as reducing sugars. Non-reducing sucrose was determined indirectly, after conversion to its constitutive monomers glucose and fructose by hydrolysis, and analysis with a relative error from -2.41 to 2.09%. Honey, apple juice, and milk samples were evaluated as commercial products. The results obtained with the proposed assay compared to those of the alkaline Cu(II) -Nc reference method were found close to each other, and compatible with the label values of commercial products. The accuracy of the developed method was performed by spiking glucose to honey and lactose to milk samples using two different concentrations. The obtained recoveries with respect to the post-column HPLC method were between 97 and 105% for honey and 96-107% for milk. The method gave linear responses against sugar concentration with correlation coefficients greater than 0.996 for the four analytes (glucose, fructose, maltose and lactose) in a range of 9.0 - 342.3 mg L-1 with LOD values <= 7.4 mg L-1. With the developed method, it was possible to sensitively determine reducing sugars in various food samples at a lower temperature of post-column reaction (compared to literature values) with easy application of low cost reagents requiring minimal preliminary operation. (C) 2021 Elsevier B.V. All rights reserved.
URI
http://hdl.handle.net/20.500.12627/174702
https://doi.org/10.1016/j.chroma.2021.462664
Collections
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypes

My Account

LoginRegister

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV