Reverse torque values of abutment screws after dynamic loading: The effects of sealant agents and the taper of conical connections.

Yazar
Dayan, Suleyman
Isık-Ozkol, Gulbahar
Gencel, Burc
Ozdiler, Arda
Üst veri
Tüm öğe kaydını göster
Özet
The purpose of this in vitro study was to evaluate the influence of taper angle in internal conical connections of implant systems and the application of chlorhexidine gel as an antibacterial agent or polyvinyl siloxane sealant on reverse torque values of abutment screws after dynamic loading. Four implant systems having different taper angles (5.48, 128, 458, 608) were tested in this study. Test specimens were divided into 3 groups: control (neither chlorhexidine gel filled nor silicone sealed), 2% chlorhexidine gel filled, and silicone sealed. The samples were subjected to a dynamic load of 50 N at 1 Hz for 500 000 cycles before reverse torque measurements. The taper angle of conical connections presented a quantitative positive correlation between the degree of the taper angle and the percentage of tightening torque loss. However, it was significant only between 608 angled connection and others except for the sealant applied groups (P = .013 for control groups and P = .007 for chlorhexidine groups). The percentages of decrease in torque values of silicon sealant-applied specimens were significantly higher than both the control and chlorhexidine groups (P values are .001, .002, .001, and .002, respectively, according to increasing taper angles), but the percentage of decrease in torque values due to chlorhexidine application was not statistically significant when compared with control groups. Gel form chlorhexidine application as an antibacterial agent does not significantly affect the implant-abutment connection stability under dynamic loads. Polyvinyl siloxane sealant may cause screw loosening under functional loads.
Bağlantı
http://hdl.handle.net/20.500.12627/174685
https://doi.org/10.1563/aaid-joi-d-19-00228
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV