• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   Home
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • View Item
  •   Home
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Evaluation of right ventricular function in patients with tetralogy of Fallot using the myocardial performance index and isovolumic acceleration: a comparison with cardiac magnetic resonance imaging

Date
2014
Author
Koca, Bulent
Gokalp, Selman
GulerEroglu, Ayse
Dursen, Memduh
Yilmaz, Ravza Sümeyye
Oztunc, Funda
Metadata
Show full item record
Abstract
Background: Assessment of right ventricular function is a key point in the follow-up of operated patients with tetralogy of Fallot. Cardiac magnetic resonance assessment of right ventricular function is considered the gold standard. However, this technique is expensive, has limited availability, and requires significant expertise to acquire and interpret the images. Myocardial performance index and isovolumic acceleration have recently been studied for the assessment of right ventricular function and are shown to be simple yet powerful tools for assessing patients with right ventricular dysfunction of various origins. Methods: In this study, the integrity of myocardial performance index and isovolumic acceleration obtained by tissue Doppler imaging echocardiography to quantify right ventricular function was assessed in 31 patients operated for tetralogy of Fallot. Myocardial performance index and isovolumic acceleration measurements were compared with the parameters derived by cardiac magnetic resonance imaging. Results: In this study, a significant correlation has not been detected between cardiac magnetic resonance-originated right ventricular ejection fraction, pulmonary regurgitation fraction and myocardial performance index, isovolumic acceleration obtained by tissue Doppler imaging echocardiography from the lateral tricuspid annulus of the right ventricle. Conclusion: We have concluded that when evaluated separately, myocardial performance index and isovolumic acceleration obtained from tissue Doppler imaging echocardiography can be used in the long-term follow-up of patients who have been operated for tetralogy of Fallot, but that they do not show correlation with cardiac magnetic resonance-originated right ventricle ejection fraction and pulmonary regurgitation fraction.
URI
http://hdl.handle.net/20.500.12627/165123
https://doi.org/10.1017/s1047951113000504
Collections
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypes

My Account

LoginRegister

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV