• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

The effect of the mandibular plane angle on fracture line stability: An ex vivo experimental study

Tarih
2019
Yazar
Ben Said, Muhammed
Yildirimturk, Senem
Sirin, Yigit
Üst veri
Tüm öğe kaydını göster
Özet
Background/Aims Mandibular angle fractures fixated with plate osteosynthesis techniques have to withstand the effects of muscle attachments. Individual variations in the craniofacial morphology may alter the biomechanical resistance of the bone-plate construct. The aim of the present study was to determine the influence of variations in the mandibular plane angle (MPa) on the biomechanical stability of sheep mandibular angle fractures (MAFs). Materials and Methods Sixty sheep hemi-mandibles were used. The mandibles were positioned on a test jig that simulated low (15 degrees, group L), normal (25 degrees, group N), and high (35 degrees, group H) MPa. Unfavorable MAFs were created with thin diamond cutting disks. One four-hole, 9.0-mm-spacing, standard titanium miniplate of 2.0 mm thickness and 5.0-mm-long screws were inserted at the superior border of the alveolar bone in monoplanar orientation. Specimens were then subjected to vertical loads between 10 N and 150 N in a universal testing machine. The displacement values at each 10 N force increment and the load magnitude at which 3.0 mm displacement limit was reached were recorded. Results Starting from 40 N, the displacement values at each 10 N increment in the H group were significantly higher than those of the L and N groups until 150 N (P < 0.05). The force magnitude required to reach 3.0 mm of displacement in the H group was significantly lower than that for the L and N groups (P < 0.05 for each). Conclusions The one-miniplate monoplanar fixation technique used in sheep MAF with high MPa is more likely to offer lower biomechanical resistance to the vertical forces applied over the molar region than do the normal and low MPa.
Bağlantı
http://hdl.handle.net/20.500.12627/156139
https://doi.org/10.1111/edt.12465
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV