• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Vibration-Response Imaging Versus Quantitative Perfusion Scintigraphy in the Selection of Patients for Lung-Resection Surgery

Tarih
2011
Yazar
Comce, Fatma
Bingol, Zuleyha
Ece, Turhan
Cagatay, Pembe
Kiyan, ESEN
Toker, Alper
Tanju, Serhan
Üst veri
Tüm öğe kaydını göster
Özet
BACKGROUND: In patients being considered for lung-resection surgery, quantitative perfusion scintigraphy is used to predict postoperative lung function and guide the determination of lung-resection candidacy. Vibration-response imaging has been proposed as a noninvasive, radiation-free, and simpler method to predict postoperative lung function. We compared vibration-response imaging to quantitative perfusion scintigraphy for predicting postoperative FEV1 and diffusing capacity of the lung for carbon monoxide (D-LCO). METHODS: We enrolled 35 candidates for lung resection. Twenty-five patients had preoperative FEV1 and D-LCO measurements. RESULTS: The vibration-response-imaging measurements showed strong correlation with the quantitative-perfusion-scintigraphy measurements of predicted postoperative FEV1 % (r = 0.87, P < .001), predicted postoperative FEV1 (r = 0.90, P < .001), and predicted postoperative D-LCO% (r = 0.90, P < .001). There was a correlation between predicted postoperative FEV1 (To and L) measured via quantitative perfusion scintigraphy and the actual postoperative FEV1 (% and L) (r = 0.47, P = .048, r = 0.73, P < .001). There was no difference between the vibration-response-imaging measurements and the actual postoperative measurements of predicted postoperative FEV1 (% and L). There was a correlation between predicted postoperative FEV1 (% and L) measured via vibration-response imaging and actual postoperative FEV1 (% and L) (r = 0.52, P = .044, r = 0.79, P < .001). The mean differences between the predicted and actual postoperative FEY, values were 49 mL with vibration-response imaging, versus 230 mL with quantitative perfusion scintigraphy. Neither the vibration-response imaging nor the quantitative perfusion scintigraphy predicted postoperative D-LCO% values agreed with the actual postoperative D-LCO% values. CONCLUSIONS: Vibration-response imaging may be a good alternative to quantitative perfusion scintigraphy in evaluating lung-resection candidacy.
Bağlantı
http://hdl.handle.net/20.500.12627/139497
https://doi.org/10.4187/respare.01059
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV