Prediction of dust particle size effect on efficiency of photovoltaic modules with ANFIS: An experimental study in Aegean region, Turkey

Author
AKGÜNDOĞDU, ABDURRAHİM
ADIGÜZEL, Ertuğrul
ÖZER, Emre
Yilmaz, Aysel Ersoy
Metadata
Show full item record
Abstract
In this study, the effect of coal dust in variable sizes and weight on photovoltaic (PV) modules' performance has been examined under laboratory conditions. Experimental studies have been performed under Standard Test Conditions (STC: Radiance: 1000 W/m(2); Cell temperature: 25 degrees C; Sun Spectrum: AM 1.5) for monocrystalline silicon (m-Si) and polycrystalline silicon (p-Si) PV modules. By using sieve analysis, the particle sizes of coal dust have been divided into six groups which are in mu m size and as follows: (- 38), (+ 38/- 53), (+ 53/- 75), (+ 75/-106), (+ 106/- 250), (+ 250/- 500). Artificial pollution has been created by uniformly distributing coal dust of certain size and weight onto PV modules. Three different weights of coal dust (5 g, 10 g and 15 g) have been employed for every single size of coal dust. In order to investigate the effect of any particle size and any weight of coal, the performance of PV modules has been investigated by measuring voltage, current and power. The data set consisting of electrical parameters has been used to develop a model by using Adaptive Neuro-Fuzzy Inference System (ANFIS). Comparison of experimental and ANFIS results have been given by calculating of Root Mean Square Error (RMSE) and coefficient of determination (R-2). The performance indices have been calculated as RMSE = 0.18719 and R-2 = 0.99803 for m-Si, RMSE = 0.87098 and R-2 = 0.99714 for p-Si PV modules. According to the results, for a given particle size and weight, the ANFIS model is quite successful in power estimation for PV modules.
URI
http://hdl.handle.net/20.500.12627/133009
https://doi.org/10.1016/j.solener.2018.12.012
Collections
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypes

My Account

LoginRegister

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV