A Practical LC-MS/MS Method for the Detection of NDMA at Nanogram per Liter Concentrations in Multiple Water Matrices

Date
2012
Author
Pehlivanoglu-Mantas, Elif
Aydin, Egemen
Topuz, Emel
Metadata
Show full item record
Abstract
N-nitrosodimethylamine (NDMA) is one of the most important disinfection by-products (DBPs) due to its carcinogenicity even at low concentrations which correspond to the levels occurring in drinking water and wastewater effluents. Therefore, NDMA is a candidate DBP that is expected to be regulated in the near future. However, the measurement of NDMA in the low nanogram per liter range is challenging because of the limitations of analytical techniques including both the sample preparation and the LC-MS/MS. Moreover, the accuracy of most of the current methods is only tested for drinking water and no information is present for other matrices. In this study, a combination of solid-phase extraction (SPE) and LC-MS/MS method that does not require high-resolution MS or advanced techniques for sample pretreatment is developed. Moreover, important factors that affect the optimization of the SPE method are provided to enable readers to optimize their own SPE procedures if necessary. The proposed method was validated for surface water, groundwater, and wastewater samples and the method quantification limit was 2 ng/L. In addition, the proposed method was used to determine the concentration of NDMA precursors measured as NDMA formation potential (NDMAFP) throughout a drinking water treatment plant at two different sampling periods. NDMAFP decreased by approximately 40 % in both samples. The concentrations ranged between 4 and 11.5 ng/L and the presence of these low concentrations underlines the need for an easy to use, yet sensitive method for the determination of NDMA in environmental matrices.
URI
http://hdl.handle.net/20.500.12627/100078
https://doi.org/10.1007/s11270-012-1315-1
Collections
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypes

My Account

LoginRegister

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV