Basit öğe kaydını göster

dc.contributor.authorTas, B.
dc.contributor.authorOzturk, S. Tokdemir
dc.contributor.authorBilge, Hatice
dc.date.accessioned2021-03-05T07:29:04Z
dc.date.available2021-03-05T07:29:04Z
dc.identifier.citationTas B., Bilge H., Ozturk S. T. , "An Investigation of the Dose Distribution Effect Related with Collimator Angle for VMAT Method", 9th International Physics Conference of the Balkan-Physical-Union (BPU), İstanbul, Türkiye, 24 - 27 Ağustos 2015, cilt.1722
dc.identifier.othervv_1032021
dc.identifier.otherav_94094e26-09a4-4112-b06c-c7ebed17084b
dc.identifier.urihttp://hdl.handle.net/20.500.12627/99745
dc.identifier.urihttps://doi.org/10.1063/1.4944204
dc.description.abstractAim of this study is to investigate the efficacy of dose distribution in eleven prostate cancer patients with single VMAT and double VMAT when varying collimator angle. We generated optimum single and double VMAT treatment plans when collimator angle was 0 degrees. We recalculated single VMAT plans at different collimator angles(0 degrees, 15 degrees, 30 degrees, 45 degrees, 60 degrees, 75 degrees, 90 degrees) for double VMAT plans(0 degrees-0 degrees, 15 degrees-345 degrees, 30 degrees-330 degrees, 45 degrees-315 degrees, 60 degrees-300 degrees, 75 degrees-285 degrees, 90 degrees-270 degrees) without changing any optimization parameters. HI, DVH and %95 dose coverage of PTV calculated and analyzed. We determined better dose distribution with some collimator angles. Plans were verified using the 2 dimensional ion chamber array Matrixx (R) and 3 dimensional Compass (R) software program. A higher % 95 dose coverage of PTV was found for single VMAT in the 15 degrees collimator angle, for double VMAT in the 60 degrees-300 degrees and 75 degrees-285 degrees collimator angles. Because of lower rectum doses, we suggested 75 degrees-285 degrees. When we compared single and double VMAT's dose distribution, we had better % 95 dose coverage of PTV and lower HI with double VMAT. Our result was significant statistically. These finds are informative for choosing 75 degrees-285 degrees collimator angles in double VMAT plans for prostate cancer.
dc.language.isoeng
dc.subjectTemel Bilimler
dc.subjectTemel Bilimler (SCI)
dc.subjectFizik
dc.subjectFİZİK, UYGULAMALI
dc.titleAn Investigation of the Dose Distribution Effect Related with Collimator Angle for VMAT Method
dc.typeBildiri
dc.contributor.departmentTokat Gaziosmanpaşa Üniversitesi , ,
dc.identifier.volume1722
dc.contributor.firstauthorID26471


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster