Basit öğe kaydını göster

dc.contributor.authorTogrol, Ergun
dc.contributor.authorBozbey, Ilknur
dc.date.accessioned2021-03-04T17:38:38Z
dc.date.available2021-03-04T17:38:38Z
dc.date.issued2010
dc.identifier.citationBozbey I., Togrol E., "Correlation of standard penetration test and pressuremeter data: a case study from Istanbul, Turkey", BULLETIN OF ENGINEERING GEOLOGY AND THE ENVIRONMENT, cilt.69, sa.4, ss.505-515, 2010
dc.identifier.issn1435-9529
dc.identifier.otherav_868808a0-6b56-4dd9-af59-6a4e24ee1334
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/91423
dc.identifier.urihttps://doi.org/10.1007/s10064-009-0248-4
dc.description.abstractIn this study, correlations were obtained between standard penetration test (SPT) and pressuremeter data measured during an extensive geotechnical investigation conducted in Istanbul, Turkey. In this context, SPT blow counts (N) were correlated with pressuremeter modulus (E (PMT)) and limit pressure (p (L)). Empirical equations were proposed to estimate limit pressure from pressuremeter modulus, and E (PMT)/p (L) ratios were calculated and evaluated. An attempt was also made to correlate limit pressure to undrained shear strength (s (u)) measured by unconfined compression strength test. Correlations were carried out for sandy and clayey soils separately. The quantity (total of 182) and quality of the data (use of same equipment and procedures during data acquisition in a well defined geological setting) mean the obtained correlations may be valuable for similar soils. It is anticipated that the correlations obtained may help designers in evaluating, comparing, interpreting or cross checking the soil parameters obtained from these two important in situ tests.
dc.language.isoeng
dc.subjectYER BİLİMİ, MULTİDİSİPLİNER
dc.subjectYerbilimleri
dc.subjectTemel Bilimler (SCI)
dc.subjectJEOLOJİ
dc.subjectJeoloji Mühendisliği
dc.subjectMühendislik ve Teknoloji
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMÜHENDİSLİK, JEOLOJİK
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, ÇEVRE
dc.titleCorrelation of standard penetration test and pressuremeter data: a case study from Istanbul, Turkey
dc.typeMakale
dc.relation.journalBULLETIN OF ENGINEERING GEOLOGY AND THE ENVIRONMENT
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume69
dc.identifier.issue4
dc.identifier.startpage505
dc.identifier.endpage515
dc.contributor.firstauthorID67978


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster