Basit öğe kaydını göster

dc.contributor.authorGuray Efes, Begum
dc.contributor.authorTiryaki, Murat
dc.contributor.authorYAMAN, Batu Can
dc.contributor.authorGumustas, Burak
dc.date.accessioned2021-03-04T14:44:42Z
dc.date.available2021-03-04T14:44:42Z
dc.date.issued2013
dc.identifier.citationGuray Efes B., YAMAN B. C. , Gumustas B., Tiryaki M., "The effects of glass ionomer and flowable composite liners on the fracture resistance of open-sandwich class II restorations", DENTAL MATERIALS JOURNAL, cilt.32, sa.6, ss.877-882, 2013
dc.identifier.issn0287-4547
dc.identifier.otherav_832aa680-6d84-483d-adc9-b4bc49b4103b
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/89291
dc.identifier.urihttps://doi.org/10.4012/dmj.2013-053
dc.description.abstractThis in vitro study aimed to investigate the effects of glass-ionomer and flowable composite liners on the fracture resistance of Class II amalgam and composite restorations. Group 1 cavities were restored with amalgam and Group 4 cavities with nanofill composite after the application of a dentin-bonding agent. For the remaining groups, light-cured-glass-ionomer liner was used in a gingival floor proximal box (Groups 2, 5) or flowable composite was used as a liner (Groups 3, 6), the remainder of the cavity was restored with amalgam (Groups 2, 3) or composite (Groups 5, 6). The restorations were loaded in compression to failure. The data was analyzed using Tukey's multiple comparison test. The fracture resistance was significantly higher (p0.05). Flowable composite, glass-ionomer liners increased the fracture resistance of open-sandwich Class II amalgam restorations.
dc.language.isoeng
dc.subjectDiş Hekimliği
dc.subjectMühendislik ve Teknoloji
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectMalzeme Bilimi
dc.subjectMALZEME BİLİMİ, BİYOMATERYAL
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.titleThe effects of glass ionomer and flowable composite liners on the fracture resistance of open-sandwich class II restorations
dc.typeMakale
dc.relation.journalDENTAL MATERIALS JOURNAL
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume32
dc.identifier.issue6
dc.identifier.startpage877
dc.identifier.endpage882
dc.contributor.firstauthorID71325


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster