Basit öğe kaydını göster

dc.contributor.authorBaran, Mehmet
dc.contributor.authorBilir, Turhan
dc.contributor.authorCANBAY, ERDEM
dc.contributor.authorSevil, Tugce
dc.date.accessioned2021-03-04T14:39:46Z
dc.date.available2021-03-04T14:39:46Z
dc.date.issued2011
dc.identifier.citationSevil T., Baran M., Bilir T., CANBAY E., "Use of steel fiber reinforced mortar for seismic strengthening", CONSTRUCTION AND BUILDING MATERIALS, cilt.25, sa.2, ss.892-899, 2011
dc.identifier.issn0950-0618
dc.identifier.otherav_82ba0bda-7385-4aa2-8f1f-d3ec0f579bd3
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/89024
dc.identifier.urihttps://doi.org/10.1016/j.conbuildmat.2010.06.096
dc.description.abstractThe objective of this research was to develop an economical, structurally effective, and practically applicable steel fiber reinforced mortar (SFRM) which could be applied onto the hollow brick infills of a reinforced concrete (RC) structure. Masonry walls were almost converted into strong and rigid infills with the application of SFRM. Two different mix proportions were produced with the composition of Portland cement, fine aggregate, water, and plasticizer or bonding agent as the chemical admixture. Tests were carried out to determine the optimum steel fiber content (1%, 2%, or 4% by volume) and to clarify the use of plasticizer or bonding agent in the mortar in the context of sticking ability, flexural, compressive, and adhesion strengths. As a result, mortar with plasticizer and 2% steel fiber (by volume) came out to be the optimum mortar mixture as strengthening material. The performance of RC frame strengthened with SFRM containing plasticizer and 2% steel fiber by volume was compared to those of the hollow brick infilled RC frame without strengthened mortar and the hollow brick infilled RC frame with reference mortar. It was observed that the specimen strengthened with the optimum mortar mix satisfied the target objectives of this study. (C) 2010 Elsevier Ltd. All rights reserved.
dc.language.isoeng
dc.subjectMühendislik ve Teknoloji
dc.subjectMALZEME BİLİMİ, MULTIDISCIPLINARY
dc.subjectYapı
dc.subjectMalzeme Bilimi
dc.subjectİnşaat Mühendisliği
dc.subjectMÜHENDİSLİK, SİVİL
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectİNŞAAT VE YAPI TEKNOLOJİSİ
dc.titleUse of steel fiber reinforced mortar for seismic strengthening
dc.typeMakale
dc.relation.journalCONSTRUCTION AND BUILDING MATERIALS
dc.contributor.departmentOrta Doğu Teknik Üniversitesi , ,
dc.identifier.volume25
dc.identifier.issue2
dc.identifier.startpage892
dc.identifier.endpage899
dc.contributor.firstauthorID104603


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster