dc.contributor.author | Poyrazoglu, E | |
dc.contributor.author | Sen, D | |
dc.contributor.author | Tuncelli, B | |
dc.date.accessioned | 2021-03-04T13:26:21Z | |
dc.date.available | 2021-03-04T13:26:21Z | |
dc.date.issued | 2004 | |
dc.identifier.citation | Sen D., Poyrazoglu E., Tuncelli B., "The retentive effects of pre-fabricated posts by luting cements", JOURNAL OF ORAL REHABILITATION, cilt.31, sa.6, ss.585-589, 2004 | |
dc.identifier.issn | 0305-182X | |
dc.identifier.other | av_7c6af80f-6490-44bb-b048-b8e968c6210c | |
dc.identifier.other | vv_1032021 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/85092 | |
dc.identifier.uri | https://doi.org/10.1111/j.1365-2842.2004.01276.x | |
dc.description.abstract | The purpose of this study was to compare the retention of two different pre-fabricated posts cemented to the root canal with four different adhesive luting cements and a zinc phosphate cement. The crowns of 100 freshly extracted human mandibular central and lateral incisors were removed at the cementoenamel junction and divided into two main groups (A = ParaPost and B = Flexi-Post) and further divided into five subgroups to evaluate the effects of five different cements (Rely-X ARC, Panavia F, ParaPost Cement, Flexi-Flow Natural and Adhesor) each with 10 samples. Post-holes were prepared on all of the roots following the manufacturer's instructions. Each sample was placed into a specialized jig and tensile strength tests performed by using testing machine with a crosshead speed of 0.638 cm min(-1) and force applied until failure. The data were analysed with one-way anova (Post Hoc a Scheffe's S test) and two-way anova (P < 0.001). The Flexi-Post dowels had a mean of 54.21 kg (s.d. = 9.37) and demonstrated statistically higher retention than ParaPost dowels with a mean of 33.93 kg (s.d. = 10.69) for all of the cement groups (P < 0.001). In Flexi-Post and ParaPost dowel groups; Rely-X ARC was statistically higher than the Panavia F, ParaPost Cement, Flexi-Flow Natural and Adhesor (P < 0.05). Adhesor was significantly lower than the other subgroups (P < 0.05). Resin luting cements have demonstrated very high tensile strength potential for a strong bond to dentin. | |
dc.language.iso | eng | |
dc.subject | Klinik Tıp (MED) | |
dc.subject | Sağlık Bilimleri | |
dc.subject | DİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP | |
dc.subject | Klinik Tıp | |
dc.subject | Tıp | |
dc.subject | Diş Hekimliği | |
dc.title | The retentive effects of pre-fabricated posts by luting cements | |
dc.type | Makale | |
dc.relation.journal | JOURNAL OF ORAL REHABILITATION | |
dc.contributor.department | , , | |
dc.identifier.volume | 31 | |
dc.identifier.issue | 6 | |
dc.identifier.startpage | 585 | |
dc.identifier.endpage | 589 | |
dc.contributor.firstauthorID | 46804 | |