Show simple item record

dc.contributor.authorBilir, Turhan
dc.contributor.authorTopcu, Ilker Bekir
dc.date.accessioned2021-03-04T12:48:01Z
dc.date.available2021-03-04T12:48:01Z
dc.date.issued2010
dc.identifier.citationTopcu I. B. , Bilir T., "Experimental investigation of drying shrinkage cracking of composite mortars incorporating crushed tile fine aggregate", MATERIALS & DESIGN, cilt.31, sa.9, ss.4088-4097, 2010
dc.identifier.issn0264-1275
dc.identifier.otherav_79189622-f7f5-4cee-a901-021d694bbee0
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/83038
dc.identifier.urihttps://doi.org/10.1016/j.matdes.2010.04.047
dc.description.abstractDrying shrinkage is generally classified as an important hardened concrete property. It expresses the strain occurring in hardened concrete due to the loss of water. During the drying process, free and absorbed water is lost from the concrete. When the drying shrinkage is restrained, cracks can occur, depending on the internal stresses in the concrete. The ingress of deleterious materials through these cracks can cause decrease in the compressive strength and the durability of concrete. In this study, being as a fine aggregate in mortars, crushed tile (CT) effect on drying shrinkage and drying shrinkage cracking is investigated. Thus, compressive and flexural strength, modulus of elasticity, and free and restrained drying shrinkage tests are conducted on mortar specimens produced with and without crushed tile fine aggregate. The ring test has been used in order to investigate the cracks induced by restrained drying shrinkage. In this way, free drying shrinkage strain, along with the number and development of drying shrinkage cracks, of the crushed tile fine aggregate mortar composites are quantified and observed. (C) 2010 Elsevier Ltd. All rights reserved.
dc.language.isoeng
dc.subjectMalzeme Bilimi
dc.subjectMALZEME BİLİMİ, MULTIDISCIPLINARY
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik ve Teknoloji
dc.titleExperimental investigation of drying shrinkage cracking of composite mortars incorporating crushed tile fine aggregate
dc.typeMakale
dc.relation.journalMATERIALS & DESIGN
dc.contributor.departmentEskişehir Osmangazi Üniversitesi , ,
dc.identifier.volume31
dc.identifier.issue9
dc.identifier.startpage4088
dc.identifier.endpage4097
dc.contributor.firstauthorID104609


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record