Show simple item record

dc.contributor.authorYanaz, Zeynep
dc.contributor.authorFilik, Hayati
dc.date.accessioned2021-03-04T09:33:11Z
dc.date.available2021-03-04T09:33:11Z
dc.identifier.citationFilik H., Yanaz Z., "A sensitive method for determining total vanadium in water samples using colorimetric-solid-phase extraction-fiber optic reflectance spectroscopy", JOURNAL OF HAZARDOUS MATERIALS, cilt.172, ss.1297-1302, 2009
dc.identifier.issn0304-3894
dc.identifier.othervv_1032021
dc.identifier.otherav_68c502a3-7006-499d-ad90-281893786993
dc.identifier.urihttp://hdl.handle.net/20.500.12627/72611
dc.identifier.urihttps://doi.org/10.1016/j.jhazmat.2009.07.136
dc.description.abstractA selective colorimetric-solid-phase extraction (C-SPE) method for the determination of total vanadium in water samples was developed. This method introduced a new variation of C-SPE. The colour reaction is based on the reaction of vanadium(V) ternary complex formed with 1-(2-Pyridylazo)-2-naphtol (PAN) in the presence hydrogen peroxide (H2O2). In this technique, the target analytes in samples are extracted onto solid matrix loaded with a colorimetric reagent and then quantified directly on the adsorbent surface by using a miniature fiber optic reflectance spectrometer. The measurements were carried out at a wavelength of 589.4 nm since it yielded the largest divergence different in reflectance spectra before and after reaction with the vanadium. The overall time required for the C-SPE procedure was similar to 20 min. The amount of concentrated V is then determined in a few seconds by using miniature reflectance spectrometer. At the optimal conditions, a calibration curve was constructed, revealing a linear range of 0.05-0.52 mg L-1 and a detection limit as low as 0.01 mg L-1 while the RSD lower than 2.8%. In order to verify the accuracy of the method. a certified reference water samples (TMDA) were analysed and the results obtained were in good agreement with the certified values. The proposed method was applied to the determination of vanadium in tap water, seawater samples with a recovery for the spiked samples in the range of 98-102%. (C) 2009 Elsevier B.V. All rights reserved.
dc.language.isoeng
dc.subjectÇevre Mühendisliği
dc.subjectMühendislik ve Teknoloji
dc.subjectTarım ve Çevre Bilimleri (AGE)
dc.subjectTarımsal Bilimler
dc.subjectÇevre / Ekoloji
dc.subjectÇEVRE BİLİMLERİ
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, ÇEVRE
dc.titleA sensitive method for determining total vanadium in water samples using colorimetric-solid-phase extraction-fiber optic reflectance spectroscopy
dc.typeMakale
dc.relation.journalJOURNAL OF HAZARDOUS MATERIALS
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume172
dc.identifier.startpage1297
dc.identifier.endpage1302