Show simple item record

dc.contributor.authorGaiser, R.
dc.contributor.authorCakmakkaya, O. S.
dc.contributor.authorSAXENA, A.
dc.contributor.authorGEORGE, E.
dc.contributor.authorRADKE, O.
dc.contributor.authorAPFEL, C. C.
dc.date.accessioned2021-03-04T09:09:03Z
dc.date.available2021-03-04T09:09:03Z
dc.date.issued2010
dc.identifier.citationAPFEL C. C. , SAXENA A., Cakmakkaya O. S. , Gaiser R., GEORGE E., RADKE O., "Prevention of postdural puncture headache after accidental dural puncture: a quantitative systematic review", BRITISH JOURNAL OF ANAESTHESIA, cilt.105, sa.3, ss.255-263, 2010
dc.identifier.issn0007-0912
dc.identifier.othervv_1032021
dc.identifier.otherav_66e2805b-20fa-4241-a529-d5564848e432
dc.identifier.urihttp://hdl.handle.net/20.500.12627/71424
dc.identifier.urihttps://doi.org/10.1093/bja/aeq191
dc.description.abstractNo clear consensus exists on how to best prevent severe headache from occurring after accidental dural puncture. We conducted a quantitative systematic review to identify all available evidence for the prevention of postdural puncture headache (PDPH) and included 17 studies with 1264 patients investigating prophylactic epidural blood patch (PEBP), epidural morphine, intrathecal catheters, and epidural or intrathecal saline. The relative risk (RR) for headache after PEBP was 0.48 [95% confidence interval (CI): 0.23-0.99] in five non-randomized controlled trials (non-RCTs) and 0.32 (0.10-1.03) in four randomized controlled trials (RCTs). The RR for epidural morphine (based on a single RCT) was 0.25 (0.08-0.78). All other interventions were based on non-RCTs and failed statistical significance, including long-term intrathecal catheters with an RR of 0.21 (0.02-2.65). There are a number of promising options to prevent PDPH, yet heterogeneity between the studies and publication bias towards small non-RCTs with positive results limits the available evidence. Thus, a large multicentre RCT is needed to determine the best preventative practices.
dc.language.isoeng
dc.subjectAnesteziyoloji
dc.subjectCerrahi Tıp Bilimleri
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectANESTEZİYOLOJİ
dc.titlePrevention of postdural puncture headache after accidental dural puncture: a quantitative systematic review
dc.typeMakale
dc.relation.journalBRITISH JOURNAL OF ANAESTHESIA
dc.contributor.departmentUniversity of California System , ,
dc.identifier.volume105
dc.identifier.issue3
dc.identifier.startpage255
dc.identifier.endpage263
dc.contributor.firstauthorID93684


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record