dc.identifier.citationErturk S., Cetin S., Atmaca S., "Simultaneous determination of moexipril hydrochloride and hydrochlorothiazide in tablets by derivative spectrophotometric and high-performance liquid chromatographic methods", JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, cilt.33, sa.3, ss.505-511, 2003
dc.identifier.issn0731-7085
dc.identifier.otherav_660f5562-8242-4a19-b894-015b298b07e3
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/70892
dc.identifier.urihttps://doi.org/10.1016/s0731-7085(03)00252-8
dc.description.abstractTwo new simple and selective assay methods have been presented for the binary mixtures of moexipril hydrochloride (MOEX) and hydrochlorothiazide (HCTZ) in pharmaceutical formulations. The first method depends on second-derivative ultraviolet spectrophotometry with zero-crossing measurements at 215 and 234 nm for MOEX and HCTZ, respectively. The assay was linear over the concentration ranges 1.0-11.0 mug ml(-1) for MOEX and 0.5-9.0 mug ml(-1) for HCTZ. The determination limits for MOEX and HCTZ were found to be 1.0 and 0.5 mug ml(-1), respectively; while the detection limits were 0.2 mug ml(-1) for MOEX and 0.1 mug ml(-1) for HCTZ. The second method was based on isocratic reversed-phase liquid chromatography by using a mobile phase acetonitrile-20 mM phosphate buffer (pH 4.0) (50:50, v/v). Lisinopril was used as an internal standard (IS) and the substances were detected at 212 nm. The linearity range for both drugs was 0.5-12.0 mug ml(-1). The determination and detection limits were found to be 0.100 and 0.010 mug ml(-1) for MOEX and 0.025 and 0.005 mug ml(-1) for HCTZ, respectively. The proposed methods were successfully applied to the determination of these drugs in synthetic mixtures and commercially available tablets with a high percentage recovery, good accuracy and precision. (C) 2003 Elsevier Science B.V. All rights reserved.
dc.language.isoeng
dc.subjectSağlık Bilimleri
dc.subjectEczacılık
dc.subjectTemel Eczacılık Bilimleri
dc.subjectYaşam Bilimleri
dc.subjectAnalitik Kimya
dc.subjectTemel Bilimler
dc.subjectKİMYA, ANALİTİK
dc.subjectKimya
dc.subjectTemel Bilimler (SCI)
dc.subjectFARMAKOLOJİ VE ECZACILIK
dc.subjectFarmakoloji ve Toksikoloji
dc.subjectYaşam Bilimleri (LIFE)
dc.titleSimultaneous determination of moexipril hydrochloride and hydrochlorothiazide in tablets by derivative spectrophotometric and high-performance liquid chromatographic methods
dc.typeMakale
dc.relation.journalJOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
dc.contributor.department, ,
dc.identifier.volume33
dc.identifier.issue3
dc.identifier.startpage505
dc.identifier.endpage511
dc.contributor.firstauthorID169543


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster