Basit öğe kaydını göster

dc.contributor.authorYuksel, Ayhan
dc.contributor.authorYildiz, Mustafa
dc.contributor.authorKorurek, Mehmet
dc.contributor.authorSAHIN, Alparslan
dc.date.accessioned2021-03-04T08:44:50Z
dc.date.available2021-03-04T08:44:50Z
dc.date.issued2012
dc.identifier.citationKorurek M., Yildiz M., Yuksel A., SAHIN A., "Simulation of Eisenmenger syndrome with ventricular septal defect using equivalent electronic system", CARDIOLOGY IN THE YOUNG, cilt.22, sa.3, ss.301-306, 2012
dc.identifier.issn1047-9511
dc.identifier.othervv_1032021
dc.identifier.otherav_64cf1215-c4d7-4853-8d0d-cba28f31aac3
dc.identifier.urihttp://hdl.handle.net/20.500.12627/70123
dc.identifier.urihttps://doi.org/10.1017/s1047951111001478
dc.description.abstractBackground: In this study, we aim to investigate the simulation of the cardiovascular system using an electronic circuit model under normal and pathological conditions, especially the Eisenmenger syndrome. Methods and Results: The Eisenmenger syndrome includes a congenital communication between the systemic and pulmonary circulation, with resultant pulmonary arterial hypertension and right-to-left reversal of flow through the defect. When pulmonary vascular resistance exceeds systemic vascular resistance, it results in hypoxaemia and cyanosis. The Westkessel model including Resistor-Inductance-Capacitance pi-segments was chosen in order to simulate both systemic and pulmonary circulation. The left and right heart are represented by trapezoidal shape stiffness for better simulation results. The Eisenmenger syndrome is simulated using a resistance (septal resistance) connected between the left ventricle and right ventricle points of the model. Matlab (R) is used for the model implementation. In this model, although there is a remarkable increase in the pulmonary artery pressure and right ventricle pressure, left ventricle pressure, aortic pressure, aortic flow, and pulmonary compliance decrease in the Eisenmenger syndrome. In addition, left-to-right septal flow reversed in these diseases. Conclusion: Our model is effective and available for simulating normal cardiac conditions and cardiovascular diseases, especially the Eisenmenger syndrome.
dc.language.isoeng
dc.subjectKardiyoloji
dc.subjectDahili Tıp Bilimleri
dc.subjectÇocuk Sağlığı ve Hastalıkları
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectPEDİATRİ
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectCARDIAC ve CARDIOVASCULAR SİSTEMLER
dc.titleSimulation of Eisenmenger syndrome with ventricular septal defect using equivalent electronic system
dc.typeMakale
dc.relation.journalCARDIOLOGY IN THE YOUNG
dc.contributor.departmentBakirkoy Dr. Sadi Konuk Research & Training Hospital , ,
dc.identifier.volume22
dc.identifier.issue3
dc.identifier.startpage301
dc.identifier.endpage306
dc.contributor.firstauthorID90274


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster