dc.identifier.citationCAN B. Z. , Boncukcuoglu R., YILMAZ A. E. , Fil B. A. , "Effect of some operational parameters on the arsenic removal by electrocoagulation using iron electrodes", JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, cilt.12, 2014
dc.identifier.issn2052-336X
dc.identifier.othervv_1032021
dc.identifier.otherav_6108660b-06fe-4563-8f79-7a017efbdd88
dc.identifier.urihttp://hdl.handle.net/20.500.12627/67684
dc.identifier.urihttps://doi.org/10.1186/2052-336x-12-95
dc.description.abstractArsenic contamination of drinking water is a global problem that will likely become more apparent in future years as scientists and engineers measure the true extent of the problem. Arsenic poisoning is preventable though as there are several methods for easily removing even trace amounts of arsenic from drinking water. In the present study, electrocoagulation was evaluated as a treatment technology for arsenic removal from aqueous solutions. The effects of parameters such as initial pH, current density, initial concentration, supporting electrolyte type and stirring speed on removal efficiency were investigated. It has been observed that initial pH was highly effective on the arsenic removal efficiency. The highest removal efficiency was observed at initial pH = 4. The obtained experimental results showed that the efficiency of arsenic removal increased with increasing current density and decreased with increasing arsenic concentration in the solution. Supporting electrolyte had not significant effects on removal, adding supporting electrolyte decreased energy consumption. The effect of stirring speed on removal efficiency was investigated and the best removal efficiency was at the 150 rpm. Under the optimum conditions of initial pH 4, current density of 0.54 mA/cm(2), stirring speed of 150 rpm, electrolysis time of 30 minutes, removal was obtained as 99.50%. Energy consumption in the above conditions was calculated as 0.33 kWh/m(3). Electrocoagulation with iron electrodes was able to bring down 50 mg/L arsenic concentration to less than 10 mu g/L at the end of electrolysis time of 45 minutes with low electrical energy consumption as 0.52 kWh/m(3).
dc.language.isoeng
dc.subjectÇevre Mühendisliği
dc.subjectMühendislik ve Teknoloji
dc.subjectTarım ve Çevre Bilimleri (AGE)
dc.subjectTarımsal Bilimler
dc.subjectÇevre / Ekoloji
dc.subjectÇEVRE BİLİMLERİ
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, ÇEVRE
dc.titleEffect of some operational parameters on the arsenic removal by electrocoagulation using iron electrodes
dc.typeMakale
dc.relation.journalJOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING
dc.contributor.departmentDevlet Su Isleri (DSI) , ,
dc.identifier.volume12
dc.contributor.firstauthorID103131


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster