dc.contributor.authorCimen, Haydar
dc.contributor.authorYengin, Esengun
dc.date.accessioned2021-03-04T07:46:06Z
dc.date.available2021-03-04T07:46:06Z
dc.date.issued2012
dc.identifier.citationCimen H., Yengin E., "Analyzing the Effects of the Platform-Switching Procedure on Stresses in the Bone and Implant-Abutment Complex by 3-Dimensional Fem Analysis", JOURNAL OF ORAL IMPLANTOLOGY, cilt.38, sa.1, ss.21-26, 2012
dc.identifier.issn0160-6972
dc.identifier.otherav_5fcdeb1a-bd9e-497d-afdf-0ede95aa2428
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/66903
dc.identifier.urihttps://doi.org/10.1563/aaid-joi-d-10-00033
dc.description.abstractThe purpose of this study was to investigate the effect of 2 different abutment types on the stress distribution in pen-implant bone and within the implant-abutment complex using 3-dimensional finite element analysis. A simple cylindrical implant (4 x 11 mm) was used in this study for efficacy calculation. One model simulated a 4.00-mm-diameter abutment connection, and the other was narrower, using a 3.2-mm-diameter abutment connection assuming a platform-switching configuration. The stress level in the cervical bone area at the implant was greatly reduced when the narrow-diameter abutment was connected compared with the regular-sized one, despite the fact that the stress level in the implant-abutment complex was increased. The results obtained in the platform-switching model can contribute to reduce the stress level at the implant-bone interface area. Results from this study showed the platform-switching procedure has the biomechanical advantage of shifting the stress concentration area away from the cervical bone-implant interface. The disadvantage of the configuration is the increasing stress in the abutment and implant-abutment junction.
dc.language.isoeng
dc.subjectKlinik Tıp (MED)
dc.subjectSağlık Bilimleri
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.subjectKlinik Tıp
dc.subjectTıp
dc.subjectDiş Hekimliği
dc.titleAnalyzing the Effects of the Platform-Switching Procedure on Stresses in the Bone and Implant-Abutment Complex by 3-Dimensional Fem Analysis
dc.typeMakale
dc.relation.journalJOURNAL OF ORAL IMPLANTOLOGY
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume38
dc.identifier.issue1
dc.identifier.startpage21
dc.identifier.endpage26