Basit öğe kaydını göster

dc.contributor.authorAsik, Mehmet Dogan
dc.contributor.authorYaprak, Bulent
dc.contributor.authorGÜÇLÜ, Burak
dc.contributor.authorKarabulut, Aylin Bilgin
dc.contributor.authorGuven, Erdem
dc.date.accessioned2021-03-03T20:34:41Z
dc.date.available2021-03-03T20:34:41Z
dc.date.issued2013
dc.identifier.citationAsik M. D. , Yaprak B., Guven E., Karabulut A. B. , GÜÇLÜ B., "A Device for the Functional Improvement of Lagophthalmos", JOURNAL OF CRANIOFACIAL SURGERY, cilt.24, sa.4, ss.1478-1482, 2013
dc.identifier.issn1049-2275
dc.identifier.otherav_5aa0868b-9f71-4aa8-a4b0-59b609c74990
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/63683
dc.identifier.urihttps://doi.org/10.1097/scs.0b013e3182903580
dc.description.abstractA new device was tested on rabbits for the improvement of lagophthalmos, which causes dryness and irritation of the eye and may cause blindness if untreated. In the presented study, 14 rabbits were injected with local anesthetic to induce temporary facial palsy leading to lagophthalmos on one side. To provide functionality to the upper eyelids, ferromagnetic steel plates were either implanted within the eyelid or taped on the eyelid surface. The device detected blinking in the nonparalytic side and moved the anesthetized paralytic eyelid by pulling the steel plate electromagnetically. The control group (n = 5) did not wear the device, and they could not shut their paralytic eyelids. The treatment group with the external placement of the metal plate (n = 4) and the treatment group with the implant (n = 5) wore the device for artificial blinking. All animals were observed during the experiments, and blinking was recorded on digital video. The data collected from video records were analyzed to test the statistical difference of blinking between control and the treated groups. The results showed that the treatment groups could artificially move their paralytic eyelids. Furthermore, the treatment group with the implant showed a noticeable similarity in eyelid position compared with healthy (nonparalytic) eyes.
dc.language.isoeng
dc.subjectKlinik Tıp (MED)
dc.subjectSağlık Bilimleri
dc.subjectCERRAHİ
dc.subjectKlinik Tıp
dc.subjectTıp
dc.subjectCerrahi Tıp Bilimleri
dc.titleA Device for the Functional Improvement of Lagophthalmos
dc.typeMakale
dc.relation.journalJOURNAL OF CRANIOFACIAL SURGERY
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume24
dc.identifier.issue4
dc.identifier.startpage1478
dc.identifier.endpage1482
dc.contributor.firstauthorID210013


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster