Show simple item record

dc.contributor.authorEryilmaz, Hamdi
dc.contributor.authorBayraktaroglu, Zubeyir
dc.contributor.authorDuru, Adil Deniz
dc.contributor.authorEmir, Uzay
dc.contributor.authorDemiralp, Tamer
dc.contributor.authorAdemoglu, Ahmet
dc.date.accessioned2021-03-03T20:27:02Z
dc.date.available2021-03-03T20:27:02Z
dc.identifier.citationDuru A. D. , Eryilmaz H., Emir U., Bayraktaroglu Z., Demiralp T., Ademoglu A., "Implementation of low resolution electro-magnetic tomography with fMRI statistical maps on realistic head models", 29th Annual International Conference of the IEEE-Engineering-in-Medicine-and-Biology-Society, Lyon, Fransa, 22 - 26 Ağustos 2007, ss.5239-5240
dc.identifier.othervv_1032021
dc.identifier.otherav_59f718ae-0f05-44f4-9e60-7242a057ecdc
dc.identifier.urihttp://hdl.handle.net/20.500.12627/63266
dc.identifier.urihttps://doi.org/10.1109/iembs.2007.4353523
dc.description.abstractFunctional neuroimaging studies can be performed by combining the modalities of fMRI and Electroencephalography because of their complementary properties. The main advantage of EEG imaging among other modalities is the high temporal resolution while fMRI has high spatial resolution. So, usage of these procedures is going to help us to gain more information about the functional organization of the brain. In this study, changes in the relationship between Steady State Visual Evoked Potentials (SSVEP) generators and BOLD responses during visual stimulation have been systematically studied with 5 stimulus presentation rates (2, 4, 6, 8, 10) between 2-10 Hz. fMRI Analysis was carried out using Statistical Parametric Mapping (SPM). The result of fMRI analysis is used as a localization mask for SSVEP localization process. SSVEP generators are localized using Low Resolution Electro Magnetic Tomography (LORETA) which is implemented on a realistic head model. Then, for each stimulus frequency voxel by voxel correlation values of the active regions are computed.
dc.language.isoeng
dc.subjectRADYOLOJİ, NÜKLEER TIP ve MEDİKAL GÖRÜNTÜLEME
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectDahili Tıp Bilimleri
dc.subjectNükleer Tıp
dc.subjectBiyomedikal Mühendisliği
dc.subjectMühendislik ve Teknoloji
dc.subjectKlinik Tıp
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, BİYOMEDİKSEL
dc.subjectKlinik Tıp (MED)
dc.subjectGÖRÜNTÜLEME BİLİMİ VE FOTOĞRAF TEKNOLOJİSİ
dc.titleImplementation of low resolution electro-magnetic tomography with fMRI statistical maps on realistic head models
dc.typeBildiri
dc.contributor.departmentBoğaziçi Üniversitesi , ,
dc.contributor.firstauthorID85487


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record