Basit öğe kaydını göster

dc.contributor.authorDikmen, B.
dc.contributor.authorTarim, B.
dc.date.accessioned2021-03-03T18:47:32Z
dc.date.available2021-03-03T18:47:32Z
dc.date.issued2018
dc.identifier.citationDikmen B., Tarim B., "The Effect of Endodontic Irrigants on the Microtensile Bond Strength of Different Dentin Adhesives", NIGERIAN JOURNAL OF CLINICAL PRACTICE, cilt.21, sa.3, ss.280-286, 2018
dc.identifier.issn1119-3077
dc.identifier.othervv_1032021
dc.identifier.otherav_510ca7e3-ab8d-4c0e-ab16-c3e9a5adbb90
dc.identifier.urihttp://hdl.handle.net/20.500.12627/57655
dc.identifier.urihttps://doi.org/10.4103/njcp.njcp_282_17
dc.description.abstractObjectives: The aim of this study was to determine the influence of irrigants on bond strength of adhesive systems. Materials and Methods: Superficial dentin surfaces of 60 extracted molars were divided into 15 groups, according to irrigants and adhesives. In the control groups, surfaces were irrigated with distilled water. In experimental groups, sodium hypochlorite (NaOCl), ethylenediaminetetraacetic acid (EDTA) + NaOCl, chlorhexidine (CHX), and NaOCl + sodium ascorbate were used as irrigants. Resin composites were then built up using Single Bond, Clearfil SE Bond, and Xeno 3 as adhesives. The microtensile bond strength of groups was determined. Data were statistically analyzed by two-way analysis of variance (ANOVA), one-way ANOVA, and the Bonferroni test. Results: NaOCl reduced bond strength of Single Bond and Clearfil SE Bond (P < 0.01). For all adhesive systems, EDTA + NaOCl-treated groups exhibited lower bond strength than control groups (P < 0.01). CHX decreased bond strength of Single Bond (P < 0.01). Application of sodium ascorbate improved compromised bond strength to NaOCl-treated dentin (P < 0.01). Conclusion: Different irrigants had several effects on bonding of different adhesives. Sodium ascorbate after NaOCl could restore compromised bond strengths.
dc.language.isoeng
dc.subjectKlinik Tıp
dc.subjectTemel Tıp Bilimleri
dc.subjectTIP, GENEL & İÇECEK
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.titleThe Effect of Endodontic Irrigants on the Microtensile Bond Strength of Different Dentin Adhesives
dc.typeMakale
dc.relation.journalNIGERIAN JOURNAL OF CLINICAL PRACTICE
dc.contributor.departmentİstanbul Medipol Üniversitesi , ,
dc.identifier.volume21
dc.identifier.issue3
dc.identifier.startpage280
dc.identifier.endpage286
dc.contributor.firstauthorID251907


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster