Basit öğe kaydını göster

dc.contributor.authorEL-Refaei, Sherif
dc.contributor.authorUslu, Ilhami
dc.contributor.authorCinaral, Ferahnaz
dc.contributor.authorSenocak, Mustafa
dc.contributor.authorKanmaz, Bedii
dc.contributor.authorSayman, Haluk B.
dc.contributor.authorAL-Nahhas, Adil
dc.contributor.authorCuocolo, Alberto
dc.contributor.authorCarril, Jose M.
dc.date.accessioned2021-03-03T18:34:21Z
dc.date.available2021-03-03T18:34:21Z
dc.date.issued2015
dc.identifier.citationSayman H. B. , Kanmaz B., Uslu I., AL-Nahhas A., Cuocolo A., Carril J. M. , Cinaral F., EL-Refaei S., Senocak M., "Utility of left lateral supine position for myocardial perfusion single-photon emission computed tomography compared with other methods of correcting inferior wall attenuation", NUCLEAR MEDICINE COMMUNICATIONS, cilt.36, sa.3, ss.268-278, 2015
dc.identifier.issn0143-3636
dc.identifier.otherav_4fcbf179-5d2c-438d-a03c-3129d4f990cb
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/56867
dc.identifier.urihttps://doi.org/10.1097/mnm.0000000000000237
dc.description.abstractIntroduction Single-photon emission computed tomography (SPECT) myocardial perfusion imaging is an accepted method for reflecting the pathophysiological significance of lesions detected by coronary angiography. However, it has an inherent drawback in terms of false-positive perfusion defects for the inferior myocardial wall. To overcome this problem, different acquisition techniques have been proposed, including the computed tomographic-based attenuation correction method. In this respect, a new imaging technique, left supine lateral position SPECT myocardial perfusion imaging with technetium-99m methoxyisobutylisonitrile (Tc-99m MIBI), has been proposed to eliminate this problem and its value has been investigated in this report.
dc.language.isoeng
dc.subjectNükleer Tıp
dc.subjectDahili Tıp Bilimleri
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectRADYOLOJİ, NÜKLEER TIP ve MEDİKAL GÖRÜNTÜLEME
dc.titleUtility of left lateral supine position for myocardial perfusion single-photon emission computed tomography compared with other methods of correcting inferior wall attenuation
dc.typeMakale
dc.relation.journalNUCLEAR MEDICINE COMMUNICATIONS
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume36
dc.identifier.issue3
dc.identifier.startpage268
dc.identifier.endpage278
dc.contributor.firstauthorID221412


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster