Basit öğe kaydını göster

dc.contributor.authorMunncu, Emre
dc.contributor.authorBilhan, Hakan
dc.contributor.authorGeckili, Onur
dc.date.accessioned2021-03-03T18:28:51Z
dc.date.available2021-03-03T18:28:51Z
dc.identifier.citationGeckili O., Munncu E., Bilhan H., "Radiographic Evaluation of Narrow-Diameter Implants After 5 Years of Clinical Function: A Retrospective Study", JOURNAL OF ORAL IMPLANTOLOGY, cilt.39, ss.273-279, 2013
dc.identifier.issn0160-6972
dc.identifier.othervv_1032021
dc.identifier.otherav_4f493631-13ed-4e7c-bd43-9afe0a9bd5ed
dc.identifier.urihttp://hdl.handle.net/20.500.12627/56552
dc.identifier.urihttps://doi.org/10.1563/aaid-joi-d-10-00158
dc.description.abstractThe use of regular-sized dental implants is generally recommended to ensure adequate bone to implant contact. However, when the width of the edentulous crest is insufficient for the placement of a regular-sized implant, the use of a narrow-diameter implant (NDI) should be considered to prevent the need for invasive reconstruction techniques such as grafting procedures. The aim of the present study was to evaluate the survival and marginal bone levels of NDIs 5 years after prosthetic loading. A total of 159 NDIs belonging to 4 brands (Straumann, Astra Tech, Biolok, Xive) were evaluated in 71 patients. Clinical and radiographic evaluations using digital panoramic radiography were carried out. Two implants failed and no progressive bone loss or periapical lesions were detected in the remaining 157 implants, which is an overall success rate of 98.74%. Mean marginal bone loss (MBL) was found 1 mm on the mesial side and 0.98 mm on the distal side of the implants. No statistically significant relationship was detected between patient age, gender, implant location, implant length, type of the prosthesis, and MBL (P > .05). Among the 4 brands used, the MBL was highest around the Biolok implants but this was significant only compared with the Astra Tech implants (P < .05). The results of the present study indicate that NDIs can be a good solution for specific clinical situations where regular-sized implants are not suitable.
dc.language.isoeng
dc.subjectDiş Hekimliği
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.titleRadiographic Evaluation of Narrow-Diameter Implants After 5 Years of Clinical Function: A Retrospective Study
dc.typeMakale
dc.relation.journalJOURNAL OF ORAL IMPLANTOLOGY
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume39
dc.identifier.startpage273
dc.identifier.endpage279
dc.contributor.firstauthorID208853


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster