Show simple item record

dc.contributor.authorKarahan, Gonca Emel
dc.contributor.authorUsta Akgul, Sebahat
dc.contributor.authorTemurhan, Sonay
dc.contributor.authorSenturk Ciftci, Hayriye
dc.contributor.authorOgret, Yeliz
dc.contributor.authorKekik Cinar, Cigdem
dc.contributor.authorOguz, Fatma
dc.date.accessioned2021-03-02T19:13:55Z
dc.date.available2021-03-02T19:13:55Z
dc.identifier.citationKekik Cinar C., Usta Akgul S., Temurhan S., Senturk Ciftci H., Ogret Y., Karahan G. E. , Oguz F., "EFI region 8 Balkan external proficiency testing for HLA typing: Results of 15 years.", International journal of immunogenetics, cilt.47, ss.158-162, 2020
dc.identifier.issn1744-3121
dc.identifier.othervv_1032021
dc.identifier.otherav_b4abb56c-0f5a-4fa8-aef6-3faab08b055f
dc.identifier.urihttp://hdl.handle.net/20.500.12627/5375
dc.identifier.urihttps://doi.org/10.1111/iji.12464
dc.description.abstractIstanbul Medical Faculty, Department of Medical Biology, as the first EFI-accredited HLA laboratory in Turkey since 1999 has been organizing both national and international quality control tests for HLA typing under the banner of the "Balkan external proficiency testing (BEPT)" encompassing countries from EFI regions 8. The first round of BEPT in 2004 was organized for low-resolution HLA-A,-B typing by molecular methods and 12 centres participated in the exercise. In 2005, low-resolution HLA-DR typing was added, and in 2007, low-resolution HLA-C and DQ typing were added to the exercise and 28 centres participated. In 2015, high-resolution (four digits or higher typing) HLA-A,-B,-C,-DR and -DQ typing added to the exercise and 40 centres participated. In the last 2 years, 2017 and 2018, the number of participating centres increased to 48 and 52, respectively. When the distribution of low-resolution typing methods applied in the exercises were investigated, it was found that 82% of the centres in the first round of BEPT in 2004 used PCR-SSP, whereas in the last round in 2018, 26% of the centres preferred SSP, while the rest used SSO (50%) or SSP and SSO (24%) methods. Methods for high-resolution typing were SBT (41%), NGS (18%), SSO (18%), SSP (6%), SBT + NGS (6%) and SBT + SSP (11%). In 15th trial for BEPT, nomenclature mistake rate was 12%, and erroneous result rate was 6% for HLA samples. The most common mistakes in the exercises were nomenclature mistakes. The EFI Standards Version 7.0 is stated "HLA type can be reported using a hyphen if homozygosity is not proven by family studies." In order to provide standard results among HLA laboratories and since accurate HLA typing leads to significant increase of graft and patient survival, quality control exercises should be performed in all HLA-based tests periodically.
dc.language.isoeng
dc.subjectDahili Tıp Bilimleri
dc.subjectTıp
dc.subjectTıbbi Genetik
dc.subjectYaşam Bilimleri
dc.subjectMoleküler Biyoloji ve Genetik
dc.subjectTemel Bilimler
dc.subjectGENETİK VE HAYAT
dc.subjectMoleküler Biyoloji ve Genetik
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectİmmünoloji
dc.subjectSağlık Bilimleri
dc.titleEFI region 8 Balkan external proficiency testing for HLA typing: Results of 15 years.
dc.typeMakale
dc.relation.journalInternational journal of immunogenetics
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume47
dc.identifier.startpage158
dc.identifier.endpage162
dc.contributor.firstauthorID2520355


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record