Show simple item record

dc.contributor.authorSolez, Kim
dc.contributor.authorOzluk, Yasemin
dc.contributor.authorMengel, Michael
dc.contributor.authorHalloran, Philip F.
dc.contributor.authorSis, Banu
dc.contributor.authorBlanco, Paula L.
dc.date.accessioned2021-03-03T16:46:06Z
dc.date.available2021-03-03T16:46:06Z
dc.date.issued2012
dc.identifier.citationOzluk Y., Blanco P. L. , Mengel M., Solez K., Halloran P. F. , Sis B., "Superiority of virtual microscopy versus light microscopy in transplantation pathology", CLINICAL TRANSPLANTATION, cilt.26, sa.2, ss.336-344, 2012
dc.identifier.issn0902-0063
dc.identifier.othervv_1032021
dc.identifier.otherav_4605b883-c46e-460b-bc74-7b3f6d11e687
dc.identifier.urihttp://hdl.handle.net/20.500.12627/50705
dc.identifier.urihttps://doi.org/10.1111/j.1399-0012.2011.01506.x
dc.description.abstractVirtual microscopy has begun to change conventional pathology practice. We tested the reliability of this new technology in transplantation pathology. We studied 40 kidney transplant biopsies for cause and compared reproducibility of Banff scores using virtual slides versus glass slides. Three glass slides per biopsy were scanned as high-resolution digital slides using Aperio ScanScope. Three pathologists independently reviewed the biopsies: twice by glass slides and twice by virtual slides. Eleven histopathological lesions were scored and used to construct diagnosis according to Banff criteria. The intra-observer reproducibility of Banff scores was substantially good using either virtual slides or glass slides (mean kappa: 0.69 vs. 0.64, p > 0.05). The inter-observer reproducibility of Banff scores was better in virtual slides than in glass slides (mean kappa: 0.42 vs. 0.28, p < 0.001). Among the lesions, transplant glomerulopathy scoring by virtual slides showed the highest inter-observer reproducibility, with a similar accuracy to glass slides. The agreement for acute rejection between virtual and glass slides was not different from the agreement between two readings of glass slides. Thus, virtual microscopy is a reliable and more reproducible technology and has several advantages over glass slides, e. g., accessibility via internet, no fading. We recommend virtual microscopy for transplant diagnostics, including utilization for clinical trials.
dc.language.isoeng
dc.subjectCerrahi Tıp Bilimleri
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectTRANSPLANTASYON
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectCERRAHİ
dc.titleSuperiority of virtual microscopy versus light microscopy in transplantation pathology
dc.typeMakale
dc.relation.journalCLINICAL TRANSPLANTATION
dc.contributor.department, ,
dc.identifier.volume26
dc.identifier.issue2
dc.identifier.startpage336
dc.identifier.endpage344
dc.contributor.firstauthorID72327


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record