Show simple item record

dc.contributor.authorMumcu, E.
dc.contributor.authorGeckili, O.
dc.contributor.authorSunbuloglu, E.
dc.contributor.authorBozdag, E.
dc.contributor.authorBilhan, H.
dc.contributor.authorKutay, O.
dc.date.accessioned2021-03-03T14:48:24Z
dc.date.available2021-03-03T14:48:24Z
dc.date.issued2010
dc.identifier.citationBilhan H., Geckili O., Mumcu E., Bozdag E., Sunbuloglu E., Kutay O., "Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone", JOURNAL OF ORAL REHABILITATION, cilt.37, sa.12, ss.900-907, 2010
dc.identifier.issn0305-182X
dc.identifier.otherav_3b89b8e9-a5b6-488f-8d92-db52bb15f83a
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/43977
dc.identifier.urihttps://doi.org/10.1111/j.1365-2842.2010.02117.x
dc.description.abstractAchievement of primary stability during surgical placement of dental implants is one of the most important factors for successful osseointegration depending on various anatomical, surgical and implant-related factors. Resonance frequency analysis (RFA) has been shown as a non-invasive and objective technique for measuring the stability of implants. The aim of this study was to evaluate the effect of some surgical and implant-related factors in enhancing primary stability and to estimate a correlation between RFA and insertion torque (IT) in proximal regions of cow ribs representing cancellous bone. Fifteen implant beds were prepared in the most proximal region of six fresh cow ribs. Ninety implants with three different shapes and two different diameters were placed with two different surgical techniques, and the primary stability was compared using RFA and IT. Significantly higher RFA and IT values were achieved when under-dimensioned drilling was used as the surgical method (P < 0 01); significantly higher IT values were obtained with the use of wider implants (P < 0 01) and partially conical Astra Tech implants showed the highest IT values (P < 0 01). When all the implants were considered, significant correlations between the IT and RFA values were noted (% 40 6, P < 0 05). Partially conical implants with a wide diameter to be placed with the modified surgical technique proposed appear to be useful in enhancing the primary stability in cancellous bone.
dc.language.isoeng
dc.subjectKlinik Tıp (MED)
dc.subjectSağlık Bilimleri
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.subjectKlinik Tıp
dc.subjectTıp
dc.subjectDiş Hekimliği
dc.titleInfluence of surgical technique, implant shape and diameter on the primary stability in cancellous bone
dc.typeMakale
dc.relation.journalJOURNAL OF ORAL REHABILITATION
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume37
dc.identifier.issue12
dc.identifier.startpage900
dc.identifier.endpage907
dc.contributor.firstauthorID198506


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record