Basit öğe kaydını göster

dc.contributor.authorSahin, Yucel
dc.contributor.authorOzkorucuklu, SABRİYE
dc.contributor.authorAlsancak, Guleren
dc.date.accessioned2021-03-03T14:26:16Z
dc.date.available2021-03-03T14:26:16Z
dc.date.issued2011
dc.identifier.citationOzkorucuklu S., Sahin Y., Alsancak G., "Determination of Sulfamethoxazole in Pharmaceutical Formulations by Flow Injection System/HPLC with Potentiometric Detection using Polypyrrole Electrode", JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, cilt.22, sa.11, ss.2171-2177, 2011
dc.identifier.issn0103-5053
dc.identifier.othervv_1032021
dc.identifier.otherav_3982f959-7f98-4623-bd04-edabc4c0aaad
dc.identifier.urihttp://hdl.handle.net/20.500.12627/42698
dc.identifier.urihttps://doi.org/10.1590/s0103-50532011001100021
dc.description.abstractIn this work, it was used a polypyrrole (PPy) electrode as a potentiometric electrochemical detector in a flow injection system in order to determine sulfamethoxazole in pharmaceutical formulations. The PPy electrode was prepared by cyclic voltammetry in acetonitrile solution. A linear relationship was observed over the concentration range of 2.5 x 10(-5)-1.25 x 10(-3) mol L(-1) with a correlation coefficient of 0.9977 and limit of detection (LOD) of 1.03 x 10(-6) mol L(-1) (SIN = 3). The recoveries in tablet and syrup formulations were found as 97.4 and 90.8% with the relative standard deviations of 0.62 and 1.04%, respectively, which closely agree with those measured by high performance liquid chromatography (HPLC) with UV detector. Therefore, it was concluded that the PPy electrode can be used as an alternative novel potentiometric detector material for determination of sulfamethoxazole in pharmaceuticals with the advantages of easy preparation and regeneration capability of the electrode surface.
dc.language.isoeng
dc.subjectTemel Bilimler (SCI)
dc.subjectKİMYA, MULTİDİSİPLİNER
dc.subjectKimya
dc.subjectBiyokimya
dc.subjectTemel Bilimler
dc.subjectAlkoloidler
dc.titleDetermination of Sulfamethoxazole in Pharmaceutical Formulations by Flow Injection System/HPLC with Potentiometric Detection using Polypyrrole Electrode
dc.typeMakale
dc.relation.journalJOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY
dc.contributor.departmentAnadolu Üniversitesi , ,
dc.identifier.volume22
dc.identifier.issue11
dc.identifier.startpage2171
dc.identifier.endpage2177
dc.contributor.firstauthorID101983


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster