Basit öğe kaydını göster

dc.contributor.authorUlu, Sevgi
dc.date.accessioned2021-03-03T13:41:00Z
dc.date.available2021-03-03T13:41:00Z
dc.date.issued2013
dc.identifier.citationUlu S., "Determination of Methoxamine in Human Plasma and Urine by a Validated HPLC-Fluorescence Detection Method", JOURNAL OF AOAC INTERNATIONAL, cilt.96, sa.5, ss.987-990, 2013
dc.identifier.issn1060-3271
dc.identifier.othervv_1032021
dc.identifier.otherav_35645652-6fc2-409a-96e0-2666dbfba408
dc.identifier.urihttp://hdl.handle.net/20.500.12627/40096
dc.identifier.urihttps://doi.org/10.5740/jaoacint.10-479
dc.description.abstractA sensitive HPLC method for the determination of methoxamine in human plasma and urine is described. The method is based on derivatization of methoxamine with 4-chloro-7-nitrobenzofurazan in borate buffer of pH 9.5 to yield a yellow, fluorescent product. Isocratic HPLC separation was achieved on an Inertsil C-18 column (250x4.6 mm id, 5 mu m particle size) using the mobile phase methanol water (60+40, v/v) at a flow rate of 1.2 mL/min. Fluorescence detection was used at excitation and emission wavelengths of 458 and 521 nm, respectively. The assay was linear over the concentration ranges of 10-250 and 20-300 ng/mL for plasma and urine, respectively. The LOD values were 3.3 and 6.8 ng/mL and the LOQ values were 10 and 20 ng/mL for plasma and urine, respectively. The extraction recoveries were more than 97.10%. After strict validation, the method indicated good performance in terms of linearity, sensitivity, precision, accuracy (recovery), robustness, and system suitability, and it was successfully applied to the determination of methoxamine in human plasma and urine.
dc.language.isoeng
dc.subjectMühendislik ve Teknoloji
dc.subjectKİMYA, ANALİTİK
dc.subjectKimya
dc.subjectTemel Bilimler (SCI)
dc.subjectGIDA BİLİMİ VE TEKNOLOJİSİ
dc.subjectTarım Bilimleri
dc.subjectTarım ve Çevre Bilimleri (AGE)
dc.subjectTarımsal Bilimler
dc.subjectZiraat
dc.subjectGıda Mühendisliği
dc.subjectAnalitik Kimya
dc.subjectTemel Bilimler
dc.titleDetermination of Methoxamine in Human Plasma and Urine by a Validated HPLC-Fluorescence Detection Method
dc.typeMakale
dc.relation.journalJOURNAL OF AOAC INTERNATIONAL
dc.contributor.departmentİstanbul Üniversitesi , Eczacılık Fakültesi , Temel Eczacılık Bilimleri Bölümü
dc.identifier.volume96
dc.identifier.issue5
dc.identifier.startpage987
dc.identifier.endpage990
dc.contributor.firstauthorID61790


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster