Basit öğe kaydını göster

dc.contributor.authorGray, David
dc.contributor.authorAbuqbeitah, Mohammad
dc.contributor.authorDEMİR, Mustafa
dc.contributor.authorYEYİN, Nami
dc.contributor.authorSager, Sait
dc.date.accessioned2021-03-02T17:32:15Z
dc.date.available2021-03-02T17:32:15Z
dc.date.issued2020
dc.identifier.citationAbuqbeitah M., DEMİR M., YEYİN N., Sager S., Gray D., "Thyroid uptake test with portable device (COTI) after I-131 tracer administration: proof of concept", RADIATION AND ENVIRONMENTAL BIOPHYSICS, cilt.59, ss.553-558, 2020
dc.identifier.issn0301-634X
dc.identifier.othervv_1032021
dc.identifier.otherav_d8b991d8-4a23-4755-95c4-8d6ca8c3c407
dc.identifier.urihttp://hdl.handle.net/20.500.12627/3965
dc.identifier.urihttps://doi.org/10.1007/s00411-020-00849-8
dc.description.abstractCOTI (collar therapy indicator) has been recently introduced for the detection of gamma rays with emphasis on thyroid investigations. The aim of this study was to test the feasibility of a prototype version of COTI including activity detectors with low sensitivity in performing thyroid uptake measurements for a large group of patients. Consequently, thyroid uptake tests were carried out for a total of 89 patients (22 males and 67 females; age: 44 +/- 13 years) with thyroid cancer (n = 74), hyperthyroidism (n = 16) at 2 and 24 h after administration of 0.44-2 MBq of I-131. Eight individuals among the thyroid cancer patients were monitored up to 96 h after administration. The COTI device was equipped with two CsI (Tl) detectors, known as LoHi type, sensitive to activity ranges from 0.02 to 30 MBq of I-131. The uptake values from COTI were compared with those measured with a standard probe. It was found that the mean uptake of thyroid activity in thyroid cancer patients was 2.1 +/- 1.3% at 2 h when measured with the standard probe, while it was 2.2 +/- 1.2% when measured with COTI. In addition, the average uptake at 24 h after administration was 2.5 +/- 3.2% and 3.2 +/- 3.8% measured with COTI and the standard probe, respectively. A strong correlation was found at 24 h between the results obtained with COTI and the standard probe, while a weaker correlation was seen at 2 h. Overall, there was no significant difference between the results obtained with the standard probe and those obtained with COTI at both 2 and 24 h (P-value >= 0.05). Besides, 85% of the uptake values measured with COTI were less than those measured with the standard probe at the 24 h after administration. The average uptake value was 0.9 +/- 0.8% after 96 h by COTI, and 1.4 +/- 1.3% by the standard probe. Pertaining to the hyperthyroidism patients, COTI showed mean uptake values of 20 +/- 16% and 23 +/- 18% at 2 and 24 h, respectively. In contrast, the standard probe suggested higher mean uptake values of 26 +/- 18% and 30 +/- 22%, respectively. It is concluded that the prototype of COTI used in the present study has been proved to be a feasible and promising tool in thyroid investigations. It is noted, however, that the next COTI generation should include detectors equipped with collimator and energy discrimination.
dc.language.isoeng
dc.subjectKlinik Tıp
dc.subjectKlinik Tıp (MED)
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectTemel Tıp Bilimleri
dc.subjectÇevre / Ekoloji
dc.subjectÇEVRE BİLİMLERİ
dc.subjectBİYOFİZİK
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectBiyofizik
dc.subjectBiyokimya
dc.subjectTıbbi Biyoloji
dc.subjectDahili Tıp Bilimleri
dc.subjectNükleer Tıp
dc.subjectTarım ve Çevre Bilimleri (AGE)
dc.subjectÇevre Mühendisliği
dc.subjectYaşam Bilimleri
dc.subjectTemel Bilimler
dc.subjectMühendislik ve Teknoloji
dc.subjectTarımsal Bilimler
dc.subjectRADYOLOJİ, NÜKLEER TIP ve MEDİKAL GÖRÜNTÜLEME
dc.subjectBiyoloji ve Biyokimya
dc.subjectBİYOLOJİ
dc.titleThyroid uptake test with portable device (COTI) after I-131 tracer administration: proof of concept
dc.typeMakale
dc.relation.journalRADIATION AND ENVIRONMENTAL BIOPHYSICS
dc.contributor.departmentİstanbul Üniversitesi-Cerrahpaşa , ,
dc.identifier.volume59
dc.identifier.issue3
dc.identifier.startpage553
dc.identifier.endpage558
dc.contributor.firstauthorID2280930


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster