dc.contributor.author | Tunc, Recep | |
dc.contributor.author | Caglayan-Tunc, Aygul | |
dc.contributor.author | Kisakol, Gurcan | |
dc.contributor.author | Unler, Gulhan Kanat | |
dc.contributor.author | Hidayetoglu, Taha | |
dc.contributor.author | Yazici, Hasan | |
dc.date.accessioned | 2021-03-03T13:23:37Z | |
dc.date.available | 2021-03-03T13:23:37Z | |
dc.date.issued | 2007 | |
dc.identifier.citation | Tunc R., Caglayan-Tunc A., Kisakol G., Unler G. K. , Hidayetoglu T., Yazici H., "Intraobserver and interobserver agreements of leg circumference measurements by tape measure based on 3 reference points", ANGIOLOGY, cilt.58, sa.5, ss.593-596, 2007 | |
dc.identifier.issn | 0003-3197 | |
dc.identifier.other | av_33cefc13-8bbd-45dd-9167-32e080c16257 | |
dc.identifier.other | vv_1032021 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/39061 | |
dc.identifier.uri | https://doi.org/10.1177/0003319707307844 | |
dc.description.abstract | The objective of this study was to evaluate the intraobserver and interobserver agreements in tape measurements of the ankle and calf circumference with due emphasis on the 3 main reference points, the patella, the tibial tuberosity, and the medial malleolus. The leg circumference at 2 locations was measured in 66 patients in the mornings of 2 consecutive days by 6 observers. Finally, a blinded couple measured leg circumferences at a line created on calves with a ballpoint pen of 68 outpatients to calculate interobserver agreement for lined regions. Leg circumference measurement was accepted as correct when the difference was less than 0.6 cm in 2 occasions. Intraobserver and interobserver agreements were calculated as the percentage of correct measurements. Chi-square test was used to compare intraobserver and interobserver agreements for each reference point. At the calf region, intraobserver and interobserver agreements based on the tibial tuberosity (88% and 81 %) were better than those of the patella (65% and 57%) and the medial malleolus (73% and 65%). On the other hand, at above the ankle region, the agreements (79% and 62%) were also better than those of the patella (60% and 43%) and nearly the same as those of the medial malleolus (86% and 65%). Finally, interobserver agreement of the measurements at the created line with ballpoint pen (96%) was better when compared to those of the tibial tuberosity (81%), the patella (57%), and medial malleolus (65%) (p = 0.005, p < 0.001, and p < 0.001, respectively). The results of this study suggest that the tibial tuberosity as a reference point for leg circumference measurement has better intraobserver and interobserver agreements than those of the patella and the medial malleoli. | |
dc.language.iso | eng | |
dc.subject | Sağlık Bilimleri | |
dc.subject | Tıp | |
dc.subject | Klinik Tıp (MED) | |
dc.subject | Klinik Tıp | |
dc.subject | PERİFERAL VASKÜLER HASTALIĞI | |
dc.title | Intraobserver and interobserver agreements of leg circumference measurements by tape measure based on 3 reference points | |
dc.type | Makale | |
dc.relation.journal | ANGIOLOGY | |
dc.contributor.department | , , | |
dc.identifier.volume | 58 | |
dc.identifier.issue | 5 | |
dc.identifier.startpage | 593 | |
dc.identifier.endpage | 596 | |
dc.contributor.firstauthorID | 184894 | |