Show simple item record

dc.contributor.authorEreees, S.
dc.contributor.authorUysal, B.
dc.contributor.authorGumuser, G.
dc.contributor.authorParlak, Y.
dc.contributor.authorDemir, Mustafa
dc.contributor.authorCavdar, I.
dc.contributor.authorSayit, E.
dc.contributor.authorKoc, M.
dc.contributor.authorKaya, G. Capa
dc.date.accessioned2021-03-03T12:47:25Z
dc.date.available2021-03-03T12:47:25Z
dc.date.issued2016
dc.identifier.citationParlak Y., Demir M., Cavdar I., Ereees S., Gumuser G., Uysal B., Kaya G. C. , Koc M., Sayit E., "Bone marrow radiation dosimetry of high dose I-131 treatment in differentiated thyroid carcinoma patients", INTERNATIONAL JOURNAL OF RADIATION RESEARCH, cilt.14, sa.2, ss.99-104, 2016
dc.identifier.issn2322-3243
dc.identifier.othervv_1032021
dc.identifier.otherav_3028d84d-5f09-4a6a-a1bb-7cbbc435db27
dc.identifier.urihttp://hdl.handle.net/20.500.12627/36860
dc.description.abstractBackground: Radiation absorbed dose to the red bone marrow, a critical organ in the therapy of thyroid carcinoma, is generally kept below 2 Gy for non-myeloablative therapies. The aim of this study was to calculate bone marrow radiation dose by using MIRDOSE3 package program and to optimize the safe limit of activity to be administered to the thyroid cancer patients. Materials and Methods: In this study, 83 thyroid cancer patients were divided into 3 groups based on the amount of activity administered into the body. In the groups, 3700 MBq, 5550 MBq and 7400 MBq activities were used respectively. The curves of time-activity were drawn from blood samples counts and effective half-life and residencetime were calculated. Correlations of bone marrow radiation dose and radioiodine effective half-life were determined as a function of administered activity via ANOVA test. Tg levels and tumour diameters were compared using Spearman's correlation. Results: The effective half-lives of I-131 for three groups of whole-body, receiving 3700 MBq, 5550 MBq and 7400 MBq were calculated as 20.57 +/- 5.4, 17.8 +/- 5.8 and 18.7 +/- 3.9 hours, respectively. The average bone marrow doses for 3 groups of patients were 0.32 +/- 0.08 Gy, 0.42 +/- 0.14 Gy and 0.60 +/- 0.24 Gy, respectively. Conclusion: It was concluded that, the bone marrow dose to the patients still remains within the recommended level even a 9 er administering an activity of 7400 MBq of I-131 to the patients.
dc.language.isoeng
dc.subjectTıp
dc.subjectNükleer Tıp
dc.subjectSağlık Bilimleri
dc.subjectRADYOLOJİ, NÜKLEER TIP ve MEDİKAL GÖRÜNTÜLEME
dc.subjectKlinik Tıp
dc.subjectKlinik Tıp (MED)
dc.subjectDahili Tıp Bilimleri
dc.titleBone marrow radiation dosimetry of high dose I-131 treatment in differentiated thyroid carcinoma patients
dc.typeMakale
dc.relation.journalINTERNATIONAL JOURNAL OF RADIATION RESEARCH
dc.contributor.departmentManisa Celal Bayar Üniversitesi , ,
dc.identifier.volume14
dc.identifier.issue2
dc.identifier.startpage99
dc.identifier.endpage104
dc.contributor.firstauthorID80966


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record