Basit öğe kaydını göster

dc.contributor.authorAsci, Metin
dc.contributor.authorTezel, Okan
dc.contributor.authorKarabulut, Savas
dc.contributor.authorOzcep, Ferhat
dc.contributor.authorYildirim, Eray
dc.date.accessioned2021-03-03T11:28:32Z
dc.date.available2021-03-03T11:28:32Z
dc.date.issued2010
dc.identifier.citationOzcep F., Yildirim E., Tezel O., Asci M., Karabulut S., "Correlation between electrical resistivity and soil-water content based artificial intelligent techniques", INTERNATIONAL JOURNAL OF PHYSICAL SCIENCES, cilt.5, sa.1, ss.47-56, 2010
dc.identifier.issn1992-1950
dc.identifier.othervv_1032021
dc.identifier.otherav_2815d0ac-034b-44a5-ac31-6b9b194682ec
dc.identifier.urihttp://hdl.handle.net/20.500.12627/31806
dc.description.abstractBy using an artificial intelligent approaches, the purpose of this study is to compare water content of soils obtained from electrical resistivity in order to better results from conventional techniques system. The input variables for this system are the electrical resistivity reading, the water content laboratory measurements. The output variable is water content of soils. In this study, 148 data sets are clustered into 120 training sets and 28 testing sets for constructing the fuzzy system and validating the ability of system prediction, respectively. Soil is a heterogeneous medium consisting of liquid, solid, and gaseous phases. The solid and liquid phases play an essential role in soil spontaneous electrical phenomena and in behavior of electrical fields, artificially created in soil. For our aim, study area is selected in Istanbul (Yesilkoy, Florya, Basinkoy) and Golcuk. In this area, the electrical resistivity is measured by VES (Vertical Electrical Sounding) in many points of these locations by field resistivity equipment. For geotechnical purposes, on the soil samples from borings, soil mechanics laboratory procedures was applied and it determined the soil water contents from these samples. Relationships between soil water content and electrical parameters were obtained by curvilinear models. The ranges of our samples are changed between 1 - 50 ohm. m (for resistivity) and 20 - 60 (%, for water content). For this range, it was found that classical regression relation between resistivity (R) and water content (W) of soils was W = 49.21e(-0.017R). An artificial intelligent system (artificial neural networks, Fuzzy logic applications, Mamdani and Sugeno approaches) based on some comparisons about correlation between electrical resistivity and soil-water content, for Istanbul and Golcuk Soils in Turkey was constructed for identifying water content with electrical resistivity of soils.
dc.language.isoeng
dc.subjectDoğa Bilimleri Genel
dc.subjectTemel Bilimler
dc.subjectÇOK DİSİPLİNLİ BİLİMLER
dc.subjectTemel Bilimler (SCI)
dc.titleCorrelation between electrical resistivity and soil-water content based artificial intelligent techniques
dc.typeMakale
dc.relation.journalINTERNATIONAL JOURNAL OF PHYSICAL SCIENCES
dc.contributor.departmentSakarya Üniversitesi , ,
dc.identifier.volume5
dc.identifier.issue1
dc.identifier.startpage47
dc.identifier.endpage56
dc.contributor.firstauthorID34263


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster