dc.identifier.citationSezgin N., "Investigation of horizontal cold water discharge initial dilutions at various temperature differences using duckbill valve", DESALINATION AND WATER TREATMENT, cilt.57, sa.6, ss.2437-2445, 2016
dc.identifier.issn1944-3994
dc.identifier.otherav_1ea98fb0-23b5-4cfe-997b-23eb347a44ce
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/25753
dc.identifier.urihttps://doi.org/10.1080/19443994.2015.1022805
dc.description.abstractThermal pollution, that is a temperature change in natural water body, can have adverse effects on the organisms in the aquatic environment as river, lake, or ocean. A common cause of thermal pollution is the use of water as a cooling and heating system by power plants, liquefied natural gas (LNG) regasification terminals, and industrial manufacturers. Cold water discharges into a receiving water body, which are mainly originated from LNG regasification terminals from open cycle heating units, are a kind of thermal effluent. Disposal of cold water with an environmentally protective way can be applied as a dilution method using marine outfall systems. In order to obtain a better dilution in a marine outfall, there is a multiport diffuser at the end of the pipeline. Experimentally performed single port analysis of an outfall is a method of initial dilution investigation for performance determination of designed system. Because of the fact that cold water discharge is denser than receiving ambient water in the marine environment, it is a negatively buoyant dense jet. In this study, horizontally discharged cold water jet initial dilutions at various temperatures were experimentally investigated in a laboratory model using duckbill valve discharge port. Three discharge temperature differences were used as T-0=-3, -5, and -7 degrees C in the laboratory model for determination of the initial dilutions, S, in the cold water jet centerline. Densimetric Froude numbers (F) were calculated as 446.03, 358.43, and 321.76 for the selected temperature differences, respectively. This laboratory model study was also aimed at obtaining some experimental coefficients, such as impingement point distance, as design criteria for horizontally discharged cold water outfalls using duckbill valves.
dc.language.isoeng
dc.subjectToprak ve Su Muhafazası ve Amenajmanı
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, KİMYASAL
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectSU KAYNAKLARI
dc.subjectÇevre / Ekoloji
dc.subjectTarım ve Çevre Bilimleri (AGE)
dc.subjectTarımsal Bilimler
dc.subjectZiraat
dc.subjectToprak ve Bitki Besleme
dc.subjectMühendislik ve Teknoloji
dc.subjectKimya Mühendisliği ve Teknolojisi
dc.subjectHavza Yönetimi
dc.titleInvestigation of horizontal cold water discharge initial dilutions at various temperature differences using duckbill valve
dc.typeMakale
dc.relation.journalDESALINATION AND WATER TREATMENT
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume57
dc.identifier.issue6
dc.identifier.startpage2437
dc.identifier.endpage2445
dc.contributor.firstauthorID229852


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster