Basit öğe kaydını göster

dc.contributor.authorSelcuk, M. B.
dc.contributor.authorInce, Nazan
dc.contributor.authorOnuk, B.
dc.contributor.authorKabak, M.
dc.contributor.authorSahin, B.
dc.date.accessioned2021-03-03T09:39:05Z
dc.date.available2021-03-03T09:39:05Z
dc.date.issued2013
dc.identifier.citationOnuk B., Kabak M., Sahin B., Ince N., Selcuk M. B. , "New method for estimating the volume and volume fractions of the nasal structures in the goose (Anser anser domesticus) using computed tomography images", BRITISH POULTRY SCIENCE, cilt.54, sa.4, ss.441-446, 2013
dc.identifier.issn0007-1668
dc.identifier.otherav_1e2cedb1-fafd-4bfa-a3d0-7d0fccee19e9
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/25442
dc.identifier.urihttps://doi.org/10.1080/00071668.2013.806980
dc.description.abstract1. The conchae within the nasal cavity of poultry are important for water and energy conservation, but have not been experimentally evaluated. The aim of the present study was to determine the accuracy of volume and volume fraction estimates of the conchae, nasal septum and nasal cavity. 2. The nasal cavities of 7 adult goose heads were scanned using computed tomography (CT), with images sampled randomly at a 1/5 sampling fraction. Physical sections were obtained from the same samples, using an electric saw that had an adjustable section range, and provided 14 to 15 sections with a thickness of 2.5 mm. The section surface areas of the nasal cavity, nasal septum and conchae were estimated using the Cavalieri principle. Results obtained using the CT and physical section images were compared. Volumes and volume fractions obtained from the physical sections were accepted as the gold standard and differences in the CT images were determined. 3. Multiplication of the data obtained on the CT images with the deviation percentage of the physical sections produced normalised values. No differences were observed between the gold standard data and the CT images. While it was possible to normalise the obtained data using the gold standard values, the raw data could also be used for comparative studies because the deviations from normal would be similar for all groups. 4. Our study showed that the nasal structures could be estimated in vivo using CT images.
dc.language.isoeng
dc.subjectTarım ve Çevre Bilimleri (AGE)
dc.subjectZiraat
dc.subjectTARIM, SÜT & HAYVANCILIK BİLİMİ
dc.subjectTarım Bilimleri
dc.subjectTarımsal Bilimler
dc.subjectZootekni ve Hayvan Besleme
dc.titleNew method for estimating the volume and volume fractions of the nasal structures in the goose (Anser anser domesticus) using computed tomography images
dc.typeMakale
dc.relation.journalBRITISH POULTRY SCIENCE
dc.contributor.departmentOndokuz Mayıs Üniversitesi , ,
dc.identifier.volume54
dc.identifier.issue4
dc.identifier.startpage441
dc.identifier.endpage446
dc.contributor.firstauthorID75972


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster