Show simple item record

dc.contributor.authorOeksuez, DİDEM
dc.contributor.authorGueralp, Onur Sahin
dc.contributor.authorKaracam, Songuel Cavdar
dc.contributor.authorCepni, Kimia
dc.contributor.authorKoca, Ayse
dc.contributor.authorCepni, Ismail
dc.contributor.authorBese, Nuran
dc.date.accessioned2021-03-03T09:07:31Z
dc.date.available2021-03-03T09:07:31Z
dc.date.issued2009
dc.identifier.citationKaracam S. C. , Gueralp O. S. , Oeksuez D., Koca A., Cepni I., Cepni K., Bese N., "The investigation of fetal doses in mantle field irradiation", RADIATION PROTECTION DOSIMETRY, cilt.133, sa.3, ss.165-170, 2009
dc.identifier.issn0144-8420
dc.identifier.othervv_1032021
dc.identifier.otherav_1b587b0e-68cf-4883-81ae-09931a168541
dc.identifier.urihttp://hdl.handle.net/20.500.12627/23659
dc.identifier.urihttps://doi.org/10.1093/rpd/ncp034
dc.description.abstractTo determine clinically the fetal dose from irradiation of Hodgkin's disease during pregnancy and to quantify the components of fetal dose using phantom measurements. The fetal dose was measured with phantom measurements using thermoluminescent dosemeters (TLDs). Phantom measurements were performed by simulating the treatment conditions on an anthropomorphic phantom. TLDs were placed on the phantom 41, 44, 46.5 and 49.5 cm from the centre of the treatment field. Two TLDs were placed on the surface of the phantom. The estimated total dose to all the TLDs ranged from 8.8 to 13.2 cGy for treatment with Co-60 and from 8.2 to 11.8 cGy for 4 MV photons. It was concluded that the doses in different sections were evaluated to investigate dose changes in different points and depths of fetal tissues in phantom. Precise planning and the use of supplemental fetal shielding may help reduce fetal exposure.
dc.language.isoeng
dc.subjectÇevre Mühendisliği
dc.subjectTemel Bilimler
dc.subjectMühendislik ve Teknoloji
dc.subjectNükleer Fizik
dc.subjectÇEVRE BİLİMLERİ
dc.subjectÇevre / Ekoloji
dc.subjectTarım ve Çevre Bilimleri (AGE)
dc.subjectKAMU, ÇEVRE VE İŞ SAĞLIĞI
dc.subjectSosyal Bilimler Genel
dc.subjectSosyal Bilimler (SOC)
dc.subjectNÜKLEAR BİLİMİ VE TEKNOLOJİSİ
dc.subjectFizik
dc.subjectTemel Bilimler (SCI)
dc.subjectRADYOLOJİ, NÜKLEER TIP ve MEDİKAL GÖRÜNTÜLEME
dc.subjectKlinik Tıp
dc.subjectKlinik Tıp (MED)
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectDahili Tıp Bilimleri
dc.subjectNükleer Tıp
dc.subjectSosyal ve Beşeri Bilimler
dc.subjectSosyoloji
dc.subjectTarımsal Bilimler
dc.titleThe investigation of fetal doses in mantle field irradiation
dc.typeMakale
dc.relation.journalRADIATION PROTECTION DOSIMETRY
dc.contributor.departmentSante Plus Hospitals Group , ,
dc.identifier.volume133
dc.identifier.issue3
dc.identifier.startpage165
dc.identifier.endpage170
dc.contributor.firstauthorID72773


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record